Installation DRAGON MACH Family
Release 04 02/2021
35
Figure 11: Device status: Location of the display elements on the device (rear side of
the device)
LED Display
Color Activity
Meaning
STAT Device Status —
none
Device is starting and/or is not ready for
operation.
green lights up
Device is ready for operation.
Characteristics can be configured
red
lights up
Device is ready for operation.
Device has detected at least one error in
the monitoring results
flashes 1 time a
period
The boot parameters used when the
device has been started differ from the
boot parameters saved.
Start the device again.
flashes 4 times a
period
Device has detected a multiple IP
address
ACA Storage
medium
ACA22
ACA31
—
none
ACA storage medium not connected
green lights up
ACA storage medium connected
flashes 3 times a
period
Device writes to/reads from the storage
medium
yellow lights up
ACA storage medium inoperative
RM
Ring Manager —
none
No redundancy configured
green lights up
Redundancy exists
flashes 1 time a
period
Device is reporting an incorrect
configuration of the RM function
yellow lights up
No redundancy exists
FAN
1 ... 5
Individual fan
status
—
none
Fan X not operational.
green lights up
Fan X operational.
FAN1 FAN2
FAN3
STAT
ACA
RM
FAN4
FAN5
P
P1
P2