Release 03 05/2020
Display
Description
Curative Action
NODENUMBER
MISMATCH
Indicates a mismatch between the configured node
number on the NSM and HiProvision.
Make sure that both node numbers on the
NSM and HiProvision match.
NSM
BACKPLANETYPE
INVALID
NSM backplane type invalid
Probably the NSM is defect. Replace the NSM.
NSM
BACKPLANETYPE
MISMATCH
NSM backplane type mismatch. The configuration
on the CSM is not compatible with the node
backplane. E.g. the CSM was initially configured in
another node type (e.g. PTN2210) than the node
type in which it is intalled now (e.g. PTN2206).
Clear the CSM (=factory default) via pushing
the hidden reset button (§2.1.3) with a fine
non-conductive object and reconfigure it in
HiProvision.
NSM ERROR
NSM not reachable.
Make sure the NSM is plugged in correctly. If it
is still not reachable, replace the NSM.
NSM NODENUMBER
INVALID
The NSM cannot read its configured node number
or its node number is configured beyond the valid
node number range of 0001 to 8999. E.g. node
number 9307 generates this error. In case of this
error, 'NODE 9001' will be displayed as in the
normal cycle. 9001 is a special node number to
indicate node number problems.
Verify the configured node number and make
sure to have it configured in the valid range of
0001 to 8999. If it is in the valid range, replace
the NSM.
PSU<x> INPUT
PSU<x> input voltage missing (x = 1 or 2).
Make sure that the PSU<x> is plugged in
correctly and powered up. If the problem
persists, replace PSU<x>.
PSU<x> OUTPUT
PSU<x> output voltage missing (x = 1 or 2).
PSU<x> TEMP
PSU<x> temperature out of range (x = 1 or 2).
POE<x> FAILURE
PoE PSU<x> (Power over Ethernet) has not enough
input voltage to deliver the normal PoE power (x =
1 or 2).
Check the input voltage of the PoE PSU<x>.
S<x> IFM HWERR
The module in slot S<x> has a hardware error.
Example:
S4 IFM HWERR
Replace the IFM.
S<x> IFM
MISMATCH
The interface slot <x> has a module type mismatch.
The module plugged in in slot <x> in this node,
differs from the HiProvision configuration in that
node slot <x>.
Example:
S3 IFM MISMATCH
Make sure that the configured module in
HiProvision is the same as the module plugged
in in that specific slot.
S<x> IFM TEMP
High temperature on the IFM in interface slot<x> (x
= 1 or 2). Example:
S4 IFM TEMP
Make sure that the node has enough room
below and above the node for ventilation as
described in the installation manual in Ref. [1]
in Table 2.
S<x>
INCOMPATIBLE
MODULE
Node slot<x> has plugged in a module that is not
compatible in this slot<x>. This plugged in IFM will
not work or get any bandwidth in this slot.
Move the inserted module into another slot
that is compatible for the module. See
Ref.[100] in Table 2 to find out which slots
allow which modules.
2.1.5
HiProvision Management Port/Channel
a.
General
This RJ45 Ethernet connector must be used to manage the Dragon PTN network via
HiProvision (=Dragon PTN Management System). This connector allows HiProvision to access
the Dragon PTN management or DCN channel, which is built up dynamically between all the
connected nodes within the network.
NOTE:
DCN = Data Communication Network