Installation GRS1020/1120/1030/1130
Release 04 01/2020
51
For
every
supply voltage to be connected, perform the following steps:
Remove the terminal connector from the device.
Connect the wires according to the pin assignment on the device with the
clamps.
Fasten the wires in the terminal block by tightening the terminal screws.
You find the prescribed tightening torque in chapter:
“General technical data” on page 60
2.5.2
Supply voltage with characteristic value M
You will find information on the characteristic values here:
“Device name and product code” on page 21
You have the option of supplying the supply voltage redundantly, without
load distribution.
Both supply voltage inputs are uncoupled.
Figure 7: Supply voltage with characteristic value M: 3-pin terminal block with screw
lock
Type of the voltages
that can be
connected
Specification of the supply
voltage
Pin assignment
DC voltage
Rated voltage range
24 V DC ... 48 V DC
Voltage range incl. maximum
tolerances
18 V DC ... 60 V DC
+
Plus terminal of the supply voltage
-
Minus terminal of the supply voltage
Table 26: Supply voltage with characteristic value C: type and specification of the
supply voltage, pin assignment on the device
N
L