54
Installation GRS1020/1120/1030/1130
Release 04 01/2020
3
Making basic settings
Note:
2 or more devices configured with the same IP address can cause
unpredictable operation of your network.
Install and maintain a process that assigns a unique IP address to every
device in the network.
The IP parameters must be entered when the device is installed for the first
time. The device provides 6 options for configuring the IP addresses:
Entry via V.24 connection
Entry using the HiDiscovery protocol via the HiDiscovery or Industrial
HiVision application
Configuration via BOOTP
Configuration via DHCP
Configuration via DHCP (Option 82)
AutoConfiguration Adapter
Further information on the basic settings of the device can be found in the
“Basic Configuration” user manual.
3.1
Default settings
IP address: The device looks for the IP address using DHCP
Management password:
Login: user, password: public (read-only)
Login: admin, password: private (read/write permissions)
Parameters that can be set via the management are set to pre-defined
values in accordance with the MIB
V.24 data rate: 9600 Baud
Ring redundancy: disabled
Ethernet ports: link status is not evaluated (signal contact)
Optical 100 Mbit/s ports: 100 Mbit/s full duplex
All other ports: autonegotiation