Damped oscillation – DC supply connection
EN 61000-4-12
IEEE C37.90.1
line/ground
–
–
–
2.5 kV
EN 61000-4-12
IEEE C37.90.1
line/line
–
–
–
1 kV
Damped oscillation – data line
EN 61000-4-12
IEEE C37.90.1
line/ground
–
–
–
2.5 kV
EN 61000-4-12
line/line
–
–
–
±1 kV
Pulse magnetic field
EN 61000-4-9
–
–
300 A/m
–
a. EN 61131-2, CE, FCC – applies to all devices
b. Merchant Navy – applies to devices with the approval codes U9, UT, UX, UY, VU
c. EN 50121-4 – applies to devices with the certification codes VT, T9, TY
d. EN 61850-3, IEEE 1613 – applies to devices with the certification codes V9, VY, VU, VT
Immunity
Standard
applications
a
a. EN 61131-2, CE, FCC – applies to all devices
Merchant Navy
b
b. Merchant Navy – applies to devices with the approval codes U9, UT, UX, UY, VU
Railway
applications
(trackside)
c
c. EN 50121-4 – applies to devices with the certification codes VT, T9, TY
Substation
applications
d
d. EN 61850-3, IEEE 1613 – applies to devices with the certification codes V9, VY, VU, VT
IEC 60068-2-6, test Fc
Vibration
5 Hz ... 8.4 Hz with
0.14 in (3.5 mm)
amplitude
8.4 Hz ... 150 Hz with
1 g
–
2 Hz ... 13.2 Hz with
0.04 in (1 mm)
amplitude
13.2 Hz ... 200 Hz
with 0.7 g
–
–
–
–
2 Hz ... 9 Hz with 0.11
in (3 mm) amplitude
9 Hz ... 200 Hz with
1 g
200 Hz ... 500 Hz
with 1.5 g
IEC 60068-2-27, test Ea
Shock
15 g at 11 ms
–
–
10 g at 11 ms