Installa
tio
n
GRS1
020/
1120
/103
0/11
30
Release
04
0
1/2020
67
7.8
EMC and immunity
Note:
Use shielded data cables for gigabit transmission via copper cables. Use shielded data cables for all transmission
rates to meet the requirements according to EN 50121-4 and marine applications.
EMC interference
emission
Standard
applications
a
a. EN 61131-2, CE, FCC – applies to all devices
Merchant Navy
b
b. Merchant Navy – applies to devices with the approval codes U9, UT, UX, UY, VU
Railway
applications
(trackside)
c
c. EN 50121-4 – applies to devices with the certification codes VT, T9, TY
Substation
applications
d
d. EN 61850-3, IEEE 1613 – applies to devices with the certification codes V9, VY, VU, VT
Radiated emission
EN 55032
Class A
Class A
Class A
Class A
DNV GL Guidelines
–
EMC 1
–
–
FCC 47 CFR Part 15
Class A
Class A
Class A
Class A
EN 61000-6-4
Fulfilled
Fulfilled
Fulfilled
Fulfilled
Conducted emission
EN 55032
DC supply connection
Class A
Class A
Class A
Class A
DNV GL Guidelines
DC supply connection
–
EMC 1
–
–
FCC 47 CFR Part 15
DC supply connection
Class A
Class A
Class A
Class A
EN 61000-6-4
DC supply connection
Fulfilled
Fulfilled
Fulfilled
Fulfilled
EN 55032
Telecommunication connections
Class A
Class A
Class A
Class A
EN 61000-6-4
Telecommunication connections
Fulfilled
Fulfilled
Fulfilled
Fulfilled