The climatic threshold values listed in the technical data must be adhered
to.
The ventilation slots must not be covered so as to ensure free air
circulation.
The clearance to the ventilation slots of the housing must be at least
10 cm (3.94 in).
The installation location should be freely accessible for the installation
and for maintenance and repairs.
The LED display elements should be clearly and easily visible.
Make sure that the TP cable is far enough away from power cables and
other sources of possible electrical interference.
Make sure that the device is connected to a separate power source with
a ground connection and a main voltage in line with the technical data,
and that the device is supplied with power via a separate isolator or power
switch. It is recommended to use overvoltage protection for all devices.
Note:
The shielding ground of the connectable industrial twisted pair lines is
connected to the front panel as a conductor.
Mounting the MACH 100 as a table unit
Install the device in line with the criteria listed in
„Installing the device
and grounding“
.
Mounting the MACH 100 in a switch cabinet
The devices are designed to be mounted in a 19" rack.
Make sure there is sufficient ventilation. If necessary, provide a fan for
the 19" rack. This will prevent the basic devices from overheating.
Measure the depth of the 19" rack so as to allow the main cable, and
any power supply cables, to be fitted from the back, and the data
cables to be fitted from the front.
If you are operating the device in a 19" switch cabinet, you must install
sliding/mounting rails (not included in the delivery) to hold the weight of
the device.
Warning
If the device is installed in a 19" switch cabinet without sliding/
mounting rails, increased vibration can cause damage to the
device and/or its modules.
For more information on sliding/mounting rails and how to install them,
please contact your switch cabinet manufacturer.
Install the sliding/mounting rails in the 19" switch cabinet as instructed
by the manufacturer, and make sure the device is resting on both rails.