MACH 100
Release 04 07/10
29
Note:
Note the safety instructions in the chapter from page
4
and
only connect a supply voltage that corresponds to the type plate of
your device.
MACH 102-8TP, MACH 102-8TP-F and MACH 102-24TP-F
Figure 18: Connections for the MACH 102-8TP, MACH 102-8TP-F and
MACH 102-24TP-F on the back of the device
1 - MACH 102-8TP, MACH 102-8TP-F or MACH 102-24TP-F device
2 - Power supply 100 - 240 V AC
MACH 102-8TP-R, MACH 102-8TP-FR, MACH 102-24TP-FR
The supply voltage can be connected redundantly. Both inputs are
uncoupled. There is no distributed load. With redundant supply, the
standard voltage supply alone supplies the device. The redundant voltage
supply automatially becomes active if the standard voltage supply fails. In
the normal case, the redundant voltage supply works in stand-by mode.
The supply voltage is electrically isolated from the housing.
Figure 19: Connections for the MACH 102-8TP-R, MACH 102-8TP-FR and
MACH 102-24TP-FR on the back of the device
1 - MACH 102-8TP-R, MACH 102-8TP-FR or MACH 102-24TP-FR device
2 - Redundant power supply 100 - 240 V AC
3 - Standard power supply 100 - 240 V AC
Note:
With non-redundant supply of the main voltage, the device reports
a loss of power. You can avert this message by applying the supply
voltage via both inputs, or by changing the configuration in the
Management.
2
1
3
2
1