34
MACH 100
Release 04 07/10
You may also choose to use shielded cables. Ground the cable
shielding at one point in order to avoid causing a ground loop.
100 Mbit/s F/O connection
These ports are either SC connections or SFP slots.
100 MBit/s F/O ports enable the connection of terminal devices or
independent network segments in compliance with the IEEE 802.3
100BASE-FX standard.
These ports support:
Full or half duplex mode
State on delivery: full duplex FDX
Note:
Make sure that the LH ports are only connected with LH ports, SM
ports are only connected with SM ports, and MM ports only with MM ports.
1 Gbit/s F/O connection
These ports are SFP slots.
1 Gbit/s F/O ports enable the connection of terminal devices or
independent network segments according to the IEEE 802.3 1000BASE-
SX/1000BASE-LX standard.
These ports support:
Autonegotiation
Full duplex mode
State on delivery: autonegotiation activated.
Note:
Make sure that the LH ports are only connected with LH ports, SX
ports are only connected with SX ports, and LX ports only with LX ports.
2.2
Display elements
After the operating voltage is set up, the software starts and initializes itself.
Afterwards, the device performs a self-test. During this process, various
LEDs light up.
The process takes around 70 seconds.