42
Installation MACH1000
Release 07 08/2022
Figure 16: Power supply unit supply voltage characteristic value M
(see on page 52
“General technical data”)
:
AC voltage (right figure) or DC voltage (left figure)
Connecting
1 - Supply voltage
2 - Signal contact
For
every
supply voltage to be connected, perform the following steps:
Verify the required conditions for connecting the voltage supply.
See “Supply voltage” on page 7.
Remove the terminal connector from the device.
Connect the protective conductor with the clamp.
Connect the wires according to the pin assignment on the device with the
clamps.
Mount the terminal block on the device using screws.
2.3.3
Wiring the signal contact
Relevant for North America:
The torque for tightening the terminal block for the signal contact on the
device is 0.34 Nm (3 lb-in).
Note:
Use copper wire with cross-section AWG 20 to AWG 12 (0.5 mm
2
to
3.0 mm
2
) and stripping length12 mm.
Connection
Power supply
characteristic
value L
Power supply
characteristic
value M - V DC
Power supply
characteristic
value M - V AC
, pin 1
Protective conductor
Protective conductor
Protective conductor
-/N, pin 2
Minus terminal of the
supply voltage
Minus terminal of the
supply voltage
Neutral conductor
+/L, pin 3
Plus terminal of the
supply voltage
Plus terminal of the
supply voltage
Line conductor
Table 8:
Pin assignment of terminal block for voltage supply
1
2
Relay
-/N +/L
-/N +/L
G
Relay
1
2
Summary of Contents for Hirschmann MACH1000 Series
Page 67: ...Installation MACH1000 Release 07 08 2022 67 ...