Installation MACH102
Release 07 12/2020
11
Installation site requirements
Operate the device at the specified ambient temperature (temperature of
the ambient air at a distance of 2 in (5 cm) from the device) and at the
specified relative humidity exclusively.
When you are selecting the installation location, make sure you
observe the climatic threshold values specified in the technical data.
Use the device in an environment with a maximum pollution degree
that complies with the specifications in the technical data.
If the device is not installed in a horizontal position, it must be installed
in a control cabinet or other enclosure with fire protection properties.
The enclosure can be made of metal or plastic with fire protection
properties of at least V-1 according to IEC 60695-11-10. Bottom
openings must not exceed 2 mm in diameter.
Strain relief
Note:
If the strain relief is insufficient, there is a risk of torsion, contact
problems and creeping interruptions.
Relieve the connection points of cables and lines from mechanical
stress.
Design strain relieves in such a way that they prevent any mechanical
damage to cables, wires or conductors caused by external influences
or their own weight.
To prevent damage to device connections, connectors and cables,
follow the instructions for proper installation in accordance with DIN
VDE 0100-520:2013-06, sections 522.6, 522.7 and 522.13.