Installation MACH102
Release 07 12/2020
35
Figure 20: Connections of the MACH102-8TP-R, MACH102-8TP-FR and
MACH102-24TP-FR at the rear side of the device
1 - MACH102-8TP-R, MACH102-8TP-FR or
MACH102-24TP-FR device
2 - Redundant power supply 100 V AC ... 240 V AC
3 - Standard power supply 100 V AC ... 240 V AC
Note:
With non-redundant supply of the mains voltage, the device reports
a power failure. You can prevent this message by applying the supply
voltage via both inputs, or by changing the configuration in the
Management.
Connecting the PoE supply voltage to the M1-8TP-RJ45 PoE
media module (optional)
WARNING
ELECTRIC SHOCK
Supply only 48 V DC (PoE) SELV or ES1 or 54 V DC (PoE+) SELV or ES1
to the M1-8TP-RJ45 PoE media module.
For the PoE power supply to the M1-8TP-RJ45 PoE media module, use a
fuse of 5 A with slow-blow characteristic.
Install this device only in a switch cabinet or in an operating site with
restricted access, to which maintenance staff have exclusive access.
Never insert sharp objects (small screwdrivers, wires, etc.) into the
connection terminals for electric conductors, and do not touch the terminals.
Non-adherence to these instructions can lead to death, serious
physical injury or material damage.