Installation MACH102
Release 07 12/2020
41
Figure 23: MACH102 display elements
1 - Display elements for the device status
2 - Display elements for the port status
3 - Display elements for the port status, media module 1
4 - Display elements for the port status, media module 2
Device state
These LEDs provide information about conditions which affect the
operation of the whole device.
P - Power (green/yellow LED)
Glowing green
MACH102-8TP, MACH102-8TP-F, MACH102-24TP-F:
Supply voltage is on.
MACH102-8TP-R, MACH102-8TP-FR, MACH102-24TP-FR:
Supply voltages 1 and 2 are on.
Glowing yellow
MACH102-8TP-R, MACH102-8TP-FR, MACH102-24TP-FR:
Supply voltage 1 or 2 is on.
Not glowing
MACH102-8TP, MACH102-8TP-F, MACH102-24TP-F:
Supply voltage is below minimum value.
MACH102-8TP-R, MACH102-8TP-FR, MACH102-24TP-FR:
Supply voltages 1 and 2 are below minimum value.
RM - Ring Manager (green/yellow LED)
Glowing green
RM function active, redundant port not active
Glowing yellow
RM function active, redundant port active
Not glowing
RM function not active
Flashing green
Incorrect configuration of the HIPER-Ring (e.g. the ring is not
connected to the ring port).
Sb StandBy - Stand-by mode (green LED)
Glowing green
Stand-by mode enabled.
Not glowing
No Stand-by mode.
FAULT - Signal contact (red LED)
Glowing red
The The signal contact is open, i.e. it is indicating a detected
fault.
Not glowing
The signal contact is closed, i.e. it is not indicating a detected
fault.
RM and Stand-by - display saving processes of the AutoConfiguration Adapter (ACA)
Flashing alternately:
Error during saving process.
LEDs flash synchronously, 2
times a second
Loading configuration from the ACA.
LEDs flash synchronously, 1
times a second
Saving the configuration in the ACA.
1
3
LS DA
USB
V.24
MACH 1000
2
1
LS DA
3
4
9
10
P
StandBy
RM
FAULT
R1 R2
5
6
7
8
13
14
11
12
17
18
15
16
21
22
19
20
25
26
23
24
LS DA
LS DA
LS DA
LS DA
2
4
Summary of Contents for Hirschmann MACH102 Series
Page 62: ......