Installation MACH102
Release 07 12/2020
53
7.8
EMC and immunity
EMC interference
immunity
EN 61000-4-2
Electrostatic discharge
Contact discharge
Air discharge
6 kV
8 kV
EN 61000-4-3
Electromagnetic field
80 MHz ... 3000 MHz
max. 20 V/m
EN 61000-4-4
Fast transients (burst)
- Power line
- Data line
2 kV
4 kV
EN 61000-4-5
Voltage surges
- Power line, line/line:
- Power line, line/earth
- Data line
1 kV
2 kV
4 kV
EN 61000-4-6
Line-conducted interference voltages
150 kHz - 80 MHz
10 V
EN 61000-4-9
Pulse magnetic fields
300 A/m
EMC interference emission
EN 55032
Class A
Yes
FCC 47 CFR Part 15 Class A
Yes
Summary of Contents for Hirschmann MACH102 Series