38
Installation MACH4002
Release 16 03/2021
1.11
Management interfaces
1.11.1 V.24 interface (external management)
The V.24 interface is an RJ11 socket.
The V.24 user interface is serial and allows you to connect the following
devices directly:
External management station (VT100 terminal or PC with appropriate
terminal emulation). With this management station, the Command Line
Interface (CLI) is available to you. Furthermore, the system monitor is
available to you at the system start.
The interface casing is electrically connected to the front panel.
The V.24 interface is not electrically insulated from the supply voltage.
Figure 13: Pin assignment of the V.24 interface and the DB9 plug
You will find the order number for the terminal cable, which is ordered
separately, in the Technical Data section
(see on page 55 “Technical data”)
.
1.11.2 USB interface
The USB interface allows you to connect the AutoConfiguration Adapter
ACA22 storage medium. This is used for saving/loading the configuration
data and diagnostic information, and for loading the software.
VT100 terminal settings
Speed
9600 Baud
Data
8 bit
Stopbit
1 bit
Handshake
off
Parity
none
Figure
Pin
Function
1
VCC (VBus)
2
- Data
3
+ Data
4
Ground (GND)
Table 12: Pin assignment of the USB interface
1
1
8
5
6
2
3
5
1
2
3
4
5
6
CTS
n.c.
TX
GND
RX
RTS
RJ11
DB9
RJ11
DB9
1 2
4
3
Summary of Contents for Hirschmann MACH4002 Series
Page 71: ...Installation MACH4002 Release 16 03 2021 71 ...
Page 72: ......