Making basic settings
The IP parameters must be entered when the device is installed for the first
time. The device provides 6 options for configuring the IP addresses:
Entry via V.24 connection
Configuration via BOOTP
Configuration via DHCP
Configuration via DHCP (Option 82)
AutoConfiguration Adapter
Further information on the basic settings of the device can be found in the
“Basic Configuration” user manual.
Default settings
IP address: The device looks for the IP address using DHCP
Password for management:
Login: user; password: public (read only)
Login: admin; password: private (read and write)
V.24 data rate: 9600 Baud
Ring redundancy: disabled
Ethernet ports: link status is not evaluated (signal contact)
Optical 100 Mbit/s ports: 100 Mbit/s full duplex
Optical 10 Gbit/s ports: 10 Gbit/s full duplex
All other ports: autonegotiation
Ring manager disabled
Stand-by coupling: disabled
WARNING
UNINTENTIONAL OPERATION IN DEVICE
Install and maintain a process that assigns a unique IP address to every
device in the network.
Failure to follow these instructions can result in death, serious injury,
or equipment damage.