background image

 

Installing MAMMUTHUS 

SWITCH

 

Published on    01    01/2020

 

53

 

 

 

MTS2724-6X-MP-E

 

 

 

 

Summary of Contents for Hirschmann MAMMUTHUS MTM2700-2X

Page 1: ...on 01 01 2020 Technical support http hirschmann it support belden com User manual Installation MAMMUTHUS ACCESS LAYER DISTRIBUTION LAYER SWITCH MTS2600 2700 2800 MAMMUTHUS POWER MODULE MTM2700 PSU500 PSU120 MAMMUTHUS MEDIA MODULE MTM2700 2X ...

Page 2: ...f the software for your own use The performance characteristics described herein shall be binding only upon the express consent of the parties at the time of signing the contract This paper is produced by Belden within its capacity Belden reserves the right to change the contents of this manual without prior notice Belden does not guarantee the correctness or accuracy of the information in this ma...

Page 3: ...a module 20 1 3 Equipment view 21 1 3 1 MTS2624 4X B 21 1 3 2 MTS2724 4X FP S 21 1 3 3 MTS2724 6X MP E 22 1 3 4 MTS2748 6X MP E 23 1 3 5 MTS2824 4X S 24 1 3 6 MTS2824 6X E 25 1 3 7 MTS2824F 4X S 26 1 3 8 MTS2832TF 4X E 27 1 3 9 MTS2848 6X E 28 1 3 10 MTS2848 6X S 29 1 3 11 Power module 30 1 3 12 Media module 32 1 4 Power supply 33 1 5 Ethernet port 34 1 5 1 100 1000 Mbit s F O port 34 1 5 2 10 Gbi...

Page 4: ... 2 Install power module optional 39 2 2 1 Install power module 39 2 3 Install equipment and ground 40 2 4 Install SFP transceiver optional 41 2 5 Operate equipment 42 2 6 Connect data cable 42 2 7 Fill in the Device Label 42 3 Make basic settings 43 4 Monitor ambient air temperature 44 5 Maintenance and repair 45 6 Remove 46 6 1 Remove power module 46 6 2 Remove media module 46 6 3 Remove SFP tran...

Page 5: ...alling MAMMUTHUS SWITCH Published on 01 01 2020 5 7 4 Network range 66 7 5 Power consumption power output 67 8 Delivery item order number and accessories 68 9 Basic technical standards 69 A More support 71 ...

Page 6: ...well as safety guidelines and warnings before connecting any cable Only operate the equipment without any damaged components Make sure there is no component to be repaired in the equipment In case of any damage or failure to the equipment switch off the power and return the equipment to Belden for inspection Qualification requirements for operators Only qualified personnel are allowed to operate t...

Page 7: ...onnections the protective conductor shall be the last to be removed Do not power up the equipment during installation Requirements for North America Use 60 75 C 140 167 F or 75 C 167 F copper Cu wires only Table 1 Wire connection requirements Power voltage connection requirements Device Model The requirements below shall apply without limitation All models Meet all of the following requirements Th...

Page 8: ...75 mm North America AWG18 The cross section of the grounding conductor shall be the same as or larger than that of the power cord Power cables suitable for voltage current and physical loads shall be used The external fuse shall be installed in the conductor at the non spot position Table 2 Power voltage connection requirements ...

Page 9: ...input Shield grounding The shield grounding module of the twisted pair cable shall be connected to the front panel as a conductor When connecting a cable segment with a conductive shield braid pay attention to the possible short circuit ESD guide These modules are equipped with electrostatic sensitive components If the connection is touched these sensitive components may be damaged or their servic...

Page 10: ...ate the equipment at the maximum ambient air temperature and in stacking when to install the equipment make sure that there is at least one available rack space approx 5 cm above the equipment to allow heat to escape through the enclosure of the equipment If you operate the equipment in 19 switch cabinet install the slide rails to support the weight of the equipment Installation site requirements ...

Page 11: ...magnetic compatibility among standardization members Please submit the EU compliance statement to the authorities at the following address in accordance with the above EU directives Hirschmann Automation and Control GmbH Stuttgarter Str 45 51 72654 Neckartenzlingen Germany www belden com Warning As Class A equipment it may cause interference to the living area In such case the operator may need to...

Page 12: ...t meets the requirements for Class A digital equipment in Section 15 of FCC These requirements are intended to provide adequate protection against interference with the equipment when used in commercial environments The equipment creates and uses high frequencies and may also radiate them Failure to observe this user manual in installation or use of the equipment may cause interference with radio ...

Page 13: ...US SWITCH Published on 01 01 2020 13 About the manual This user manual about Installation contains equipment instructions safety instructions display instructions and other information required for equipment installation ...

Page 14: ...14 Installing MAMMUTHUS SWITCH Published on 01 01 2020 Legend The symbols used in this manual have the following meanings Item list Work step Subtitle ...

Page 15: ...th comprehensive functions which can provide up to 30W power for PoE PD equipment rich L2 L3 and security functions can support complex network applications Modular power supplies can provide fast field maintenance FRU and the equipment can ensure normal operation under the environment of 55 MTS2800 switch provides a complete set of access and convergence solutions and all models have redundant po...

Page 16: ...16 Installing MAMMUTHUS SWITCH Published on 01 01 2020 ...

Page 17: ...US SWITCH Published on 01 01 2020 17 Power module You may choose 1 or 2 power modules with the same input voltage LV Ethernet power supply Power modules are provided as accessories Please refer to Order number on Page 68 ...

Page 18: ...18 Installing MAMMUTHUS SWITCH Published on 01 01 2020 Media module You can select 1 media module Media modules are provided as accessories Please refer to Order number on Page 68 ...

Page 19: ...2999831 MTS2748 6X MP E 48 FE GE POE POE 4 1 10G SFP slot 1 extend media module slot 2 modular power supply unit slot advanced software 942999846 MTS2832TF 4X E 24 100 1000M SFP slot 8 FE GE TX 4 1 10G SFP slot fixed redundant power supply advanced software 942999845 MTS2824F 4X S 24 100 1000M SFP slot 4 1 10G SFP slot fixed redundant power supply basic software 942999844 MTS2824 4X S 24 FE GE TX ...

Page 20: ...MTM2700 PSU120 AC DC 120W power supply unit input 100 240V 2 0A output 12V 10A No PoE support 942999833 MTM2700 PSU500 AC DC 500W power supply unit input 100 240V 7 0A output 12VDC 10A 53 5VDC 7A PoE support 1 2 3 Media module Order number Product code Description 942999836 MTM2700 2X MTS 2700 media module 2 1 10G SFP slot ...

Page 21: ...face 5 CONSOLE port 6 Equipment status LED 7 Reset button press and hold for 5 seconds to restart the machine 8 AC power socket 9 Ground terminal 1 3 2 MTS2724 4X FP S Front view 1 Gigabit Electrical Interface status LED 2 Gigabit Electrical Interface with POE function 3 10 Gigabit Optical Interface 4 USB interface 5 CONSOLE port 6 Equipment status LED 7 Reset button press and hold for 5 seconds t...

Page 22: ...minal 1 3 3 MTS2724 6X MP E Front view 1 Gigabit Electrical Interface status LED 2 Gigabit Electrical Interface with POE function 3 10 Gigabit Optical Interface 4 USB interface 5 CONSOLE port 6 Equipment status LED Rear view 1 Interface card slot 2 Modular power supply 1 3 Modular power supply 2 4 Ground terminal ...

Page 23: ...t view 1 Gigabit Electrical Interface status LED 2 Gigabit Electrical Interface with POE function 3 10 Gigabit Optical Interface 4 USB interface 5 CONSOLE port 6 Equipment status LED Rear view 1 Interface card slot 2 Modular power supply 1 3 Modular power supply 2 4 Ground terminal ...

Page 24: ... Gigabit Electrical Interface status LED 2 Gigabit Electrical Interface 3 10 Gigabit Optical Interface 4 USB interface 5 CONSOLE port 6 Equipment status LED 7 Reset button press and hold for 5 seconds to restart the machine Rear view 1 AC power socket 2 AC power socket 3 Ground terminal ...

Page 25: ... interface 2 CONSOLE port 3 Gigabit Electrical Interface status LED 4 Gigabit Electrical Interface 5 Air inlet of equipment 6 10 Gigabit Optical Interface status LED 7 10 Gigabit Optical Interface 8 Equipment status LED Rear view 1 Air outlet of equipment 2 AC power socket 3 Ground terminal ...

Page 26: ...t of equipment 2 Gigabit Optical Interface status LED 3 Gigabit Optical Interface 4 10 Gigabit Optical Interface 5 USB interface 6 CONSOLE port 7 Equipment status LED 8 Reset button press and hold for 5 seconds to restart the machine Rear view 1 AC power socket 2 AC power socket 3 Ground terminal ...

Page 27: ...erface status LED 2 Gigabit Optical Interface 3 Gigabit Electrical Interface status LED 4 Gigabit Electrical Interface 5 10 Gigabit Optical Interface status LED 6 10 Gigabit Optical Interface 7 CONSOLE port 8 USB interface 9 Equipment status LED Rear view 1 AC power socket 2 AC power socket 3 Ground terminal ...

Page 28: ... interface 2 CONSOLE port 3 Gigabit Electrical Interface status LED 4 Gigabit Electrical Interface 5 Air inlet of equipment 6 10 Gigabit Optical Interface status LED 7 10 Gigabit Optical Interface 8 Equipment status LED Rear view 1 Air outlet of equipment 2 AC power socket 3 Ground terminal ...

Page 29: ...B interface 2 CONSOLE port 3 Gigabit Electrical Interface status LED 4 Gigabit Electrical Interface 5 Air inlet of equipment 6 10 Gigabit Optical Interface status LED 7 10 Gigabit Optical Interface 8 Equipment status LED Rear view 1 Air outlet of equipment 2 AC power socket 3 Ground terminal ...

Page 30: ...30 Installing MAMMUTHUS SWITCH Published on 01 01 2020 1 3 11 Power module ...

Page 31: ...Installing MAMMUTHUS SWITCH Published on 01 01 2020 31 ...

Page 32: ...32 Installing MAMMUTHUS SWITCH Published on 01 01 2020 1 3 12 Media module ...

Page 33: ...ing MAMMUTHUS SWITCH Published on 01 01 2020 33 1 4 Power supply You may use the power module to supply voltage to the equipment See the Power module on page 17 for information about connecting supply voltage ...

Page 34: ...rt supports Full duplex Delivery status 10 Gbit s full duplex when 10 Gbit Ethernet SFP transceiver is used 1 Gbit s full duplex when Gbit Ethernet SFP transceiver is used 1 5 3 10 100 1000 Mbit s twisted pair port The port is an RJ45 socket The 10 100 1000 Mbit s twisted pair port allows you to connect network components according to IEEE 802 3 10BASE T 100BASE TX 1000BASE T The port supports Aut...

Page 35: ...nt port The port is an RJ45 socket The port allows you to connect network components according to IEEE 802 3 10BASE T 100BASE TX The port supports Auto negotiation 100 Mbit s half duplex 100 Mbit s full duplex 10 Mbit s half duplex 10 Mbit s full duplex The port allows you to manage the equipment and upload configuration through the following protocols SNMP SSH Telnet FTP See the Command line inte...

Page 36: ... exception to the system running Power light PWR Green ON indicating all in place power modules are working normally OFF indicating an exception to the in place power modules Fan indicator FAN Green ON indicating all fan modules on the equipment are working normally OFF indicating an exception to at least one fan module on the equipment STACK indicator STACK Green Flashing indicating stacking func...

Page 37: ...ta receiving on serial port DC0 interface indicator 1000M RJ45 self contained yellow LED OFF indicating DC0 works at 10 100M or is unlinked ON indicating DC0 works at 1000M ACT RJ45 Build in green LED OFF indicating DC0 interface is unlinked ON indicating DC0 interface is linked with no data sending and receiving Flashing indicating DC0 interface is linked with data sending and receiving Port stat...

Page 38: ... connection of external management station VT100 terminal or PC with corresponding terminal simulation and thus you are allowed to establish the connection to the command line interface CLI and the system monitor 1 7 2 USB interface The switch provides two serial ports EIA TIA 232 and Micro USB 2 0 by which users can configure the switch using the PC or laptop equipped with RS 232 serial port or U...

Page 39: ... 2 1 Unpack the box for inspection Check whether the box contains all the items specified in Delivery items on page 73 Check the parts one by one for damages incurred in shipment 2 2 Install power module optional 2 2 1 Install power module Hirschmann IT provides ready to run power modules You can choose to install the power module while the equipment is running Follow the steps below Remove the co...

Page 40: ... the equipment is operated in an environment with continuous vibration load greater than 0 7g it must be additionally fixed to the switch cabinet with 2 fixed mounting brackets on the front and back of the equipment Additional mounting brackets are provided as accessories Please refer to Accessories on Page 68 Precondition Install the equipment in 19 switch cabinet by means of slide or mounting ra...

Page 41: ...ts as shown below And attach 2 mounting brackets to the back of the equipment Additional mounting brackets are provided as accessories Please refer to Accessories on Page 68 Screw the mounting bracket to the wall to secure the equipment Equipment ground The equipment has the connection of protective grounding wire The equipment is grounded by grounding screw and power socket Follow the steps below...

Page 42: ...n buildings Try to separate the power cable from the data cable sufficiently if there are copper cables used It is best to install it in a separate channel Make sure the power cable and data cable are not laid out in parallel over a long distance preferably in separate cable channels To reduce inductive coupling make sure the power and data cables intersect at 90 Use SF UTP cable conforming to ISO...

Page 43: ...onfiguring two or more devices with the same IP address may lead to the network s failure to function as expected Install and maintain a program to assign a unique IP address to each device in the network IP parameters must be entered when the equipment is installed for the first time ...

Page 44: ...ent air temperature Please refer to General technical data on Page 49 The ambient air temperature is the air temperature at a distance of 2 inches 5 cm from the equipment specifically depending on the installation conditions of the equipment for example the distance of the equipment from other devices or other objects and the output of adjacent equipment ...

Page 45: ... be triggered only when the equipment detects an error In case of any damage or failure to the equipment switch off the power and return the equipment to the plant for inspection Hirschmann IT has always been committed to improving and developing software You are required to visit our website regularly to see if the updated software version that provides additional benefits is available You may vi...

Page 46: ...basic device You can refer to the tightening torque in the General technical data on page 49 6 2 Remove media module Follow the steps below Remove screws on the front panel of the media module Press the locking lever outward to unlock the media module steps 1 and 2 Pull the media module out of the slot step 3 Seal the media module slot on the basic device with a cover plate Secure the cover plate ...

Page 47: ...stalling MAMMUTHUS SWITCH Published on 01 01 2020 47 6 3 Remove SFP transceiver Follow the steps below Unlock and pull the SFP transceiver out of the slot Seal the SFP transceiver with a protective cover ...

Page 48: ...ecting the ground wire Failure to comply with these guidelines may result in death serious injury or equipment damage Follow the steps below Disconnect the data cable Disable the supply voltage Disconnect the power cord Disconnect the ground connection To remove the equipment from the switch cabinet or wall unscrew the equipment mounting bracket ...

Page 49: ... 0kg Power supply Rated voltage range 100 VAC 240 VAC 50 Hz 60 Hz Maximum conductor diameter AWG12 2 5 mm2 Equipment ground Tighten torque Protective grounding 3 5 6 1 lb in 0 4 0 7 Nm Climatic conditions during operation Ambient air temperature 5 55 2000m Note The altitude is 2000m 4000m and the maximum working temperature decreases by 1 every 200m above sea level Humidity 10 90 RH no condensatio...

Page 50: ...ower module Tighten torque 3 5 5 2 lb in 0 4 0 6 Nm Installation of cover plate Tighten torque 3 5 5 2 lb in 0 4 0 6 Nm Power module Rated voltage range 100 VAC 240 VAC 50 Hz 60 Hz Media module Size Please refer to Size diagram on Page 40 Weight MTM2700 2X 0 16 kg Install media module Tighten torque 2 0 3 1 lb in 0 2 0 3 Nm Mount cover plate Tighten torque 2 0 3 1 lb in 0 2 0 3 Nm ...

Page 51: ...Installing MAMMUTHUS SWITCH Published on 01 01 2020 51 7 2 Dimension drawing Basic device MTS2624 4X B ...

Page 52: ...52 Installing MAMMUTHUS SWITCH Published on 01 01 2020 MTS2724 4X FP S ...

Page 53: ...Installing MAMMUTHUS SWITCH Published on 01 01 2020 53 MTS2724 6X MP E ...

Page 54: ...54 Installing MAMMUTHUS SWITCH Published on 01 01 2020 MTS2748 6X MP E ...

Page 55: ...Installing MAMMUTHUS SWITCH Published on 01 01 2020 55 MTS2832TF 4X E ...

Page 56: ...56 Installing MAMMUTHUS SWITCH Published on 01 01 2020 MTS2824F 4X S ...

Page 57: ...Installing MAMMUTHUS SWITCH Published on 01 01 2020 57 MTS2824 4X S ...

Page 58: ...58 Installing MAMMUTHUS SWITCH Published on 01 01 2020 MTS2848 6X S ...

Page 59: ...Installing MAMMUTHUS SWITCH Published on 01 01 2020 59 MTS2824 6X E ...

Page 60: ...60 Installing MAMMUTHUS SWITCH Published on 01 01 2020 MTS2848 6X E ...

Page 61: ...Installing MAMMUTHUS SWITCH Published on 01 01 2020 61 Power module MTM2700 PSU120 MTM2700 PSU500 ...

Page 62: ...62 Installing MAMMUTHUS SWITCH Published on 01 01 2020 Media module MTM2700 2X ...

Page 63: ... Power Line Class A DNV GL Guide AC DC Power Line FCC 47 CFR Part 15 AC DC Power Line Class A EN 61000 6 4 AC DC Power Line Conforming EN 55032 Signal Line Class A EN 61000 6 4 Signal Line Conforming Harmonic current EN 61000 3 2 Class A Voltage flicker EN 61000 3 3 EMC immunity Standard application Electrostatic discharge EN 61000 4 2 IEEE C37 90 3 Contact discharge 4 kV EN 61000 4 2 IEEE C37 90 ...

Page 64: ...m 3 V m IEEE 1613 80 MHz 1000 MHz Fast transient burst EN 61000 4 4 IEEE C37 90 1 AC DC Power Line 2 kV EN 61000 4 4 IEEE C37 90 1 Data cable 1 kV EN 61000 4 5 Cable ground 2 kV Voltage surge power cable IEEE 1613 Cable ground EN 61000 4 5 Cable cable 1 kV Voltage surge data cable EN 61000 4 5 Cable ground 1 kV Conducted immunity EN 61000 4 6 150 kHz 80 MHz 10 V ...

Page 65: ...ta cable EN 61000 4 12 IEEE C37 90 1 Cable ground EN 61000 4 12 Cable cable Pulsed magnet field EN 61000 4 9 Power frequency magnetic field EN 61000 4 8 30A m Voltage dips short interruptions EN 61000 4 11 AC DC Power Line 20 ms U 100 200ms U 60 500ms U 30 5s U 100 Stability Standard application IEC 60068 2 6 Test Fc Vibration 5 Hz 8 4 Hz amplitude 0 14 in 3 5 mm 8 4 Hz 150 Hz 1g IEC 60068 2 27 Te...

Page 66: ... LC SM TX1310 nm RX1550 nm 10 km 14 dB link budget at 1310 1550 nm 0 18 dB km 18 ps nmxkm BIDI TypeB LX LC SM TX1550 nm RX1310 nm 10 km 14 dB link budget at 1550 1310 nm 0 32 dB km LX LC 1550 SM 1550 nm 40 km 19 dB link budget at 1550nm 0 18 dB km Table 3 Fiber port 1G SFP module a MM multi module SM simple module LH single mode long haul b When optical fiber data is observed it includes 3dB syste...

Page 67: ...consumption power output Name Maximum power consumption Basic device 1 PSU MTS2624 4X B 26 W MTS2724 4X FP S 29 W MTS2724 6X MP E 34 W MTS2748 6X MP E 46 W MTS2832TF 4X E 60 W MTS2824F 4X S 38 W MTS2824 4X S 26 W MTS2848 6X S 55 W MTS2824 6X E 37 W MTS2848 6X E 55 W ...

Page 68: ...may have different characteristics from the equipment itself limits the influence sphere of the whole system For example if you apply IP20 accessory to IP 65 equipment the entire system will be reduced to IP20 1G SFP module Order number MTS SFP 1G TX RJ45 942 999 854 MTS SFP 1G SX LC 942 999 855 MTS SFP 1G LX LC 942 999 856 MTS SFP 1G LX LC 942 999 857 MTS SFP 1G LH LC 942 999 858 MTS SFP 1G LH LC...

Page 69: ...950 1 Information technology equipment Safety Part 1 General requirements EN 61000 3 2 Electromagnetic compatibility EMC Part 3 2 Threshold Threshold for harmonic current equipment input current 16 A per phase EN 61000 3 3 Electromagnetic compatibility EMC Part 3 3 Threshold Limitation of voltage changes voltage fluctuations and flicker in public low voltage supply systems for equipment with rated...

Page 70: ...H Published on 01 01 2020 The equipment usually meets the technical standards set forth in the latest version Only when the equipment shell has the certification mark it means that the equipment is certified to a specific standard ...

Page 71: ...T dealer or Belden directly You may search our partners addresses online at https hirschmann it support belden com For the list of local telephone numbers and email addresses for you to get direct technical support from Hirschmann IT please visit https hirschmann it support belden com The website also contains free knowledge base and software download section ...

Page 72: ...72 Installing MAMMUTHUS SWITCH Published on 01 01 2020 ...