14
Installation MS20/MS30
Release 13 09/2019
For Use in explosive atmospheres under the IECEx Scheme:
Applied Standards:
IEC 60079-0:2011 + Corr. 1:2012 + Corr. 2:2013
IEC
60079-15:2010
The Use in Hazardous Locations with explosive atmospheres is only allowed for MS20 or MS30 model
No´s. which are individually labelled
“Ex nA IIC T4 Gc” and “IECEx DEK 14.0078X” for MSxx devices and for MB20 devices
Special conditions for safe use
1. The modules shall be installed in a suitable enclosure in accordance with IEC60079-15, taking into
account the environmental conditions under which the equipment will be used.
2. Provisions shall be made to prevent the rated voltage from being exceeded by transient
disturbances of more than 119 V.
3. When the temperature under rated conditions exceeds 70 °C at the cable or conduit entry point, or
80 °C at the branching point of the conductors, the temperature specification of the selected cable
shall be in compliance with the actual measured temperature values.
4. The equipment shall only be used in an area of not more than pollution degree 2, as defined in
IEC 60664-1.
Note
1
):
The nonincendive field wiring circuit concept allows interconnection of nonincendive field
wiring apparatus and associated nonincendive field wiring apparatus using any of the wiring
methods permitted for unclassified locations when certain parametric conditions are met.
Capacity: C
0
≥ C
i
+ C
Cable
; Inductivity: L
0
≥ L
i
+ L
Cable
The maximum cable length
has to be determined as follows:
(a) max. Cable Length < (L
0
-
L
i
) / Cable
L
(
“
Cable
L
”
denotes the inductance per unit length of used cable)
and
(b) max. Cable Length < (C
0
-
C
i
) / Cable
C
(“
Cable
C
”
denotes the capacitance per unit length of used cable).
The lower value of (a) and (b) is to apply.
Manufactured in 72654 Neckartenzlingen / Germany by Hirschmann Automation and Control GmbH.
DOM: ww/yyyy (Date of manufactur: w - week, y - year. Refer to the device label).
Conditions for safe use for Industrial Ethernet Rail Switch MS20 and MS30 devices
943-435-999 according to the IECEx Certification Scheme
Page 3/3
Summary of Contents for Hirschmann MICE MS20
Page 82: ......