Installation MS20/MS30
Release 13 09/2019
39
9 - Pin 9: Output CI-B
10 - Pin 10: Input DO-B
11 - Pin 11: Shielding DO
12 - Pin 12: Output DI-B
13 - Pin 13: Voltage 12 V
14 - Pin 14: Shielding 12 V
15 - Pin 15: Not contacted
Connect the ports of the media modules plugged into the basic module as
required in order to set up your industrial Ethernet or expand your existing
network.
Install the data lines according to your requirements.
1.6
Display elements
After establishing the operating voltage, the software starts and initializes
itself. Afterwards, the device performs a self-test. During this process,
various LEDs light up. The process lasts around 60 seconds.
Figure 11: Display elements on MS20/MS30
1 - Device status
2 - Display status
3 - Port status
1
1
2
3
3
3