22
Installation OCTOPUS OS20/OS24 Managed
Release 10 08/2017
If the manual adjustment is active on the “FAULT” signal contact, then the
detected error display is independent of the setting of the signal contact.
Port status
These LEDs display port-related information. During the boot phase, they
indicate the status of the boot process.
RM
Ring
Manager
—
None
The RM function is deactivated.
Green
Lights up
The RM function is active.
The redundant port is disabled.
flashing
The device detects an incorrect
configuration of the HIPER-Ring (e.g. the
ring is not connected to the ring port).
Yellow
Lights up
The RM function is active.
The redundant port is enabled.
LED
Display
Color
Activity
Meaning
1 ... 9
Link status
—
None
Device detects an invalid or
missing link
Green
Lights up
Device detects a valid link
Flashes 1 time a period Port is switched to stand-by
Flashes 3 times a period Port is switched off
Yellow
Flashing
Device is transmitting and/or
receiving data
PoE
PoE status
Green
None
No powered device connected
Lights up
Powered device is supplied with
power
Flashes 1 time a period No power supply to the powered
device, as the total PoE output of
the device has been exceeded
Flashes 3 times a period No power supply to the powered
device, as PoE is deactivated in
the device management
LED
Display
Color
Activity
Meaning
Summary of Contents for HIRSCHMANN OCTOPUS OS20 Series
Page 45: ...Installation OCTOPUS OS20 OS24 Managed Release 10 08 2017 45 ...
Page 46: ......