24
Installation OCTOPUS OS20/OS24 Managed
Release 10 08/2017
1.8
“FAULT” signal contact
The signal contact (“FAULT“) is used to monitor the device function, and thus
supports remote diagnostics. You can specify the type of function monitoring
in the Management.
You can also use the Management to set the signal contact manually and
thus control external devices.
The potential-free signal contact (relay contact, closed circuit) reports
through a break in contact:
At least one power supply is inoperable.
The device is not operational.
The failure of the connection on at least one port.
The report of the link status can be masked by the Management for each
port. In the delivery state, is deactivated.
Errors detected during the self-diagnostic test.
Incorrect configuration of the HIPER ring.
The following condition is also reported in RM mode:
Ring redundancy reserve is available. On delivery, there is no ring
redundancy monitoring.
Applies to devices featuring supply voltage with the characteristic value A:
Along with the supply voltage, the signal contact is connected via a 5-pin M12
connector.
See “Devices featuring supply voltage with the characteristic value A” on
page 26.
You find the prescribed tightening torque in General technical data section
on page
.
Applies to devices featuring supply voltage with characteristic value F and N:
The signal contact is connected via a 5-pin M12 connector.
You find the prescribed tightening torque in General technical data section
on page
.
Figure
Pin
Operation
1
Not used
2
Fault
3
Not used
4
Not used
5
Fault
Table 6:
Pin assignment of the 5-pin M12 socket for connecting the signal contact