26
Installation OCTOPUS OS20/OS24 Managed
Release 10 08/2017
2.2
Wiring the connectors for supply voltage
and signal contact
Note:
Only connect the device to a power supply that complies to surge
voltage category II or lower.
2.2.1
Devices featuring supply voltage with the
characteristic value A
The input voltage is electrically isolated from the housing.
You have the option of supplying the supply voltage redundantly, without
load distribution.
Use a power supply cable which is suitable for the voltage, the current and
the physical load.
Hirschmann recommends a wire diameter of 0.5 mm² to 0.75 mm²
(AWG20 to AWG18).
The supply voltage and the signal contact are connected by means of a
5-pin M12 connector (“A”-coded, e.g. ELWIKA 5012 PG7 from
Hirschmann, included in the delivery).
You find the prescribed tightening torque in General technical data
section on page
WARNING
ELECTRIC SHOCK
The nominal voltage of 48 V specified for trains can temporarily exceed the
SELV threshold of 60 V based on EN 50155 para. 5.1.1.1. Use additional
measures to limit the surge voltage to 60 V or use a lower nominal voltage.
Failure to follow this instruction can result in death, serious injury, or
equipment damage.
Type and specification of the supply
voltage
Rated voltage range DC
24 V ... 48 V
Voltage range DC incl. maximum tolerances 9.6 V ... 60 V
Figure
Pin
Function
1
+ 24 ... 48 V DC (1)
2
FAULT
3
0 V
4
+ 24 ... 48 V DC (2)
5
FAULT
Table 7:
Pin assignment of the 5-pin M12 socket for connecting the supply voltage
and the signal contact