Installation OCTOPUS OS20/OS24 Managed
Release 10 08/2017
29
The signal contact is connected via a 5-pin M12 connector (“A”-coded,
e.g. ELWIKA 5012 PG7 from Hirschmann, available as accessory).
See table 6 on page 24.
You find the prescribed tightening torque in General technical data
section on page
.
Note:
The permitted cable diameter for connector ELWIKA 5012 PG7 is
0.15 in (4 mm) to 0.23 in (6 mm). To ensure the watertightness of the
OCTOPUS OS20/OS24 Managed device, only use voltage supply cables
with a diameter within the specified range.
Connect the supply voltage and signal lines.
2.3
Installing and grounding the device
Figure
Pin
Function
1
+ 72 ... 110 V DC
2
Not used
3
0 V
4
Not used
Table 9:
Pin assignment of the 4-pin 7/8" connector for connecting the supply
voltage
WARNING
ELECTRIC SHOCK
Applies to devices featuring supply voltage with the characteristic value N:
Install the device in such a way that it is protected against mechanical
forces.
Failure to follow this instruction can result in death, serious injury, or
equipment damage.
P+
N.C.
N.C.
P−