Installation OCTOPUS OS20/OS24 Managed
Release 10 08/2017
27
Connect the supply voltage and signal lines.
2.2.2
Devices featuring supply voltage with the
characteristic value F
The input voltage is electrically isolated from the housing.
You have the option of supplying the supply voltage redundantly, without
load distribution.
Use a power supply cable which is suitable for the voltage, the current and
the physical load.
Hirschmann recommends a wire diameter of 0.75 mm² to 1.0 mm²
(AWG18 to AWG16).
The supply voltage is connected via a 5-pin 7/8" connector.
You find the prescribed tightening torque in General technical data
section on page
.
WARNING
ELECTRIC SHOCK
The nominal voltage of 48 V specified for trains can temporarily exceed the
SELV threshold of 60 V based on EN 50155 para. 5.1.1.1. Use additional
measures to limit the surge voltage to 60 V or use a lower nominal voltage.
Failure to follow this instruction can result in death, serious injury, or
equipment damage.
Type and specification of the supply
voltage
Rated voltage range DC
24 V ... 48 V
Voltage range DC incl. maximum tolerances 16.8 V ... 60 V
Summary of Contents for HIRSCHMANN OCTOPUS OS20 Series
Page 45: ...Installation OCTOPUS OS20 OS24 Managed Release 10 08 2017 45 ...
Page 46: ......