30
Installation OCTOPUS OS20/OS24 Managed
Release 10 08/2017
To protect the exposed uninstalled contacts of the components from dirt,
connect the individual system components in a dry and clean working area.
When you are selecting the installation location, make sure you observe
the climatic threshold values specified in the technical data.
Prevent heat from the surroundings from affecting the device.
Applies to devices featuring supply voltage with the characteristic value F:
Take care that the temperature of the device base plate remains under
194 °F (90 °C) during operation.
You achieve this, for example, by means of one of the following
measures:
You make sure that the operating voltage of the device is at least 20 V.
You limit the total PoE output to a maximum of 47 W.
You limit the ambient temperature to a maximum of 149 °F (65 °C).
You install the device on a 1.62 ft
2
(0.15 m
2
) metal plate to which you
will connect no other heat sources.
Prepare the drill holes at the installation point.
Mount the device on a level surface with four M5 screws.
Seal all unused connections and ports with protection screws.
2.3.1
Grounding the device
The device is grounded via the separate ground screw.
WARNING
RISK OF BURNING
Applies to devices featuring supply voltage with the characteristic value N:
Only install the device in “operating sites with restricted access” based on
EN 60950-1.
Applies to devices featuring supply voltage with the characteristic value A
and F:
At ambient temperatures > 45 °C:
Install this device solely in a switch cabinet or in an operating site with
restricted access, to which maintenance staff have exclusive access.
Failure to follow this instruction can result in death, serious injury, or
equipment damage.