34
Installation OCTOPUS OS20/OS24 Managed
Release 10 08/2017
3
Making basic settings
The IP parameters must be entered when the device is installed for the first
time. The device provides 6 options for configuring IP addresses:
Entry via V.24 connection
Entry using the HiDiscovery protocol via the application HiDiscovery or
Industrial HiVision
Configuration via BOOTP
Configuration via DHCP
Configuration via DHCP Option 82
Auto Configuration Adapter
Further information on the basic settings of the device can be found in the
“Basic Configuration” user manual.
Default settings
IP address: The device looks for the IP address using DHCP
Password for management:
Login: user; password: public (read only)
Login: admin; password: private (read and write)
Parameters that can be set via the management are set to pre-defined
values in accordance with the MIB
V.24 data rate: 9600 Baud
Ring redundancy: deactivated
Ethernet ports: link status is not evaluated (signal contact)
All ports: autonegotiation
RM function (Ring Manager) not activated
RSTP (Rapid Spanning Tree) activated
HIPER-Ring not activated
WARNING
UNINTENTIONAL OPERATION IN DEVICE
Install and maintain a process that assigns a unique IP address to every
device in the network.
Failure to follow this instruction can result in death, serious injury, or
equipment damage.