Installation OCTOPUS OS3
Release 03 08/2020
23
Note:
For devices with PoE/PoE+ ports: The exact position of the PoE/PoE+
ports on the device are printed on the device. Ports with PoE/Poe+ are
marked with the PoE/PoE+ logo on the bottom right side of the port.
1.4
Power supply
1.4.1
Supply voltage with the characteristic value BB
The supply voltage can be connected redundantly. Both inputs are
uncoupled. With a non-redundant supply of the supply voltage, the device
reports the loss of a supply voltage. You can prevent this message by
applying the supply voltage via both inputs, or by changing the configuration
in the Management.
A 5-pin, “L”-coded M12 plug is available for the redundant supply of the
device.
See “Device name and product code” on page 16.
1.4.2
Supply voltage with characteristic value HH
The supply voltage can be connected redundantly. Both inputs are
uncoupled. With a non-redundant supply of the supply voltage, the device
reports the loss of a supply voltage. You can prevent this message by
applying the supply voltage via both inputs, or by changing the configuration
in the Management.
A 5-pin, “L”-coded M12 plug is available for the redundant supply of the
device.
See “Device name and product code” on page 16.
1.4.3
Supply voltage with characteristic value PP
The supply voltage can be connected redundantly. Both inputs are
uncoupled. With a non-redundant supply of the supply voltage, the device
reports the loss of a supply voltage. You can prevent this message by
applying the supply voltage via both inputs, or by changing the configuration
in the Management.
The device supports Power over Ethernet Plus according to IEEE 802.3at
(PoE+) and allows you to supply end devices with power via the twisted pair
cable, like for example IP telephones. In the delivery state, the function
Power over Ethernet Plus is activated on every port capable of PoE+.
A 5-pin, “L”-coded M12 plug is available for the redundant supply of the
device.
See “Device name and product code” on page 16.
Note:
With redundant power supply: A positive grounding is prohibited.