Input PC150/36V/48V-IP67

Rated voltage range

24 V DC to 48 V DC

Rated input current

8.0 A DC to 3.8 A DC

Power failure bridging

min. 10 ms across entire voltage range

Polarity reversal protection

Yes, via longitudinal diode

Fuse (exchangeable)

16 A (T)

Connection type

Lapp Cable Olflex 150,

Cable cross-section 2 x 2.5

mm

2

2 x terminal sleeve

Input PC150/72V/48V-IP67

Rated voltage range

72 V DC to 110 V DC

Rated input current

2.4 A DC to 1.5 A DC

Power failure bridging

min. 10 ms across entire voltage range

Polarity reversal protection

Yes, via longitudinal diode

Fuse (exchangeable)

6,3 A (T)

Connection type

Lapp Cable Olflex 150,

Cable cross-section 2 x 2.5

mm

2

2 x terminal sleeve

Efficiency

PC150/36V/48V-IP67

> 80%

PC150/72V/48V-IP67

> 80%

Output

Output voltage 

48 V DC (0 to +2% accuracy), safety low voltage (SELV) 

IEC

 60950-1

Output current (max.) 

3,2 A

Connection type

Lumberg Automation RKT 5-228

5-pin, cable cross-section 5 x 0.5

mm

2

Safety

Standards

IEC/EN

 61010-1, VDE 0411-1,

 IEC/EN61131-2

Class of protection

Class I equipment

Enclosure type

IP 67

Insulation resistance

Primary

 

– 

secondary:

 

2000

 

V

 

AC

 

Primary

 

– 

housing:

 

1000

 

V

 

AC

 

Secondary

 

– 

housing:

 

1500

 

V

 

AC

Insulation resistance

> 500 Megaohm

Approvals

Standards

IEC/EN 

61010-1

VDE 

0411-1

IEC/EN61131-2:2007

CE Declaration – 

programmable logic controllers

EN50155 Class S1 C2

Railway

 

applications

 

– 

electronic

 

systems

 

in

 

railway

 

vehicles

 

(environmental

 

requirements)

Operating Conditions

Operating temperature

permanently

-40 to +70 °C

 (-40 to 

+

158 °F)

-40 to +85 °C

 (-40 to 

+

185 °F)

for max. 10 minutes

Storage temperature

-55 to +85 °C

 (-67 to 

+

185 °F)

Protection and monitoring

Current limitation

Yes, permanent short-circuit protection

High voltage test

Routine testing in series

EMC: emitted interference - radiated

EN50022

Class A

30 MHz to 230 MHz, max. 40 dB

(µV)/m quasi-peak, 10 m distance

230 MHz to 1000 MHz, max. 47 dB

(µV)/m quasi-peak, 10 m distance

1000 MHz to 2000 MHz, max. 56 dB

(µV)/m, average, 3 m distance

FCC47 CFR Part 15

Class A

30 MHz to 88 MHz, max. 39 dB

(µV)/m, quasi-peak, 10 m distance

88 MHz to 216 MHz, max. 43.5 dB

(µV)/m, quasi-peak, 10 m distance

216 MHz to 960 MHz, max. 46.5 dB

(µV)/m, quasi-peak, 10 m distance

960 MHz to 2,000 MHz, max. 49.5 dB

(µV)/m, quasi-peak, 10 m distance

Summary of Contents for HIRSCHMANN PC150 48V-IP67 Series

Page 1: ...ge of 48 VDC from an input voltage of 72 110 VDC Permitted ambient temperature 40 to 70 C in accordance with EN50155 for max 10 minutes up to 85 C No additional cooling element necessary voltage transformer is integrated into cooling element 150 W power output Class I equipment IP67 enclosure type Conforms to EN50155 class C1 S2 Output has short circuit protection Input has polarity reversal prote...

Page 2: ...al equipment designed for use within certain voltage limits The EU declaration of conformity is kept available for the responsible authorities in accordance with the above mentioned EU directives at Hirschmann Automation and Control GmbH Stuttgarter Straße 45 51 D 72654 Neckartenzlingen www hirschmann com The product can be used in the resi dential sphere residential sphere business and trade sphe...

Page 3: ...ns of the PC150 36V 48V IP67 and PC150 72V 48V IP67 power supply units in mm 1 2 PIN ASSIGNMENTS 2 2 ATTACHING THE FERRITE A ferrite incorporated into the secondary cable is included in the delivery Fig 2 Ferrite mounted on the secondary cable of the device 2 3 CONNECTING THE SUPPLY VOLTAGE AND MOUNTING THE PROTECTIVE CONDUCTOR M Connect the protective conductor see chapter 1 2 Pin assignments bef...

Page 4: ... Class of protection Class I equipment Enclosure type IP 67 Insulation resistance Primary secondary 2000 V AC Primary housing 1000 V AC Secondary housing 1500 V AC Insulation resistance 500 Megaohm Approvals Standards IEC EN 61010 1 VDE 0411 1 IEC EN61131 2 2007 CE Declaration programmable logic controllers EN50155 Class S1 C2 Railway applications electronic systems in railway vehicles environment...

Page 5: ...r input 2 kV line earth IEC EN61000 4 6 Line conducted interference voltages 150 kHz to 80 MHz 10 V Mechanical components Dimensions without cables W x H x L 115 mm x 65 mm x 240 mm Weight 3 100 g Housing material Aluminum UL94 V0 Casting compound Polyurethane Vibration resistance IEC60068 2 6 Test Fc Test level according to IEC61131 2 EN61373 category 1 Class A broadband noise installation accord...

Page 6: ...n Automation and Control GmbH Stuttgarter Straße 45 51 D 72654 Neckartenzlingen Germany www hirschmann com Technical support https hirschmann support belden com Printed in Germany Subject to alterations 04 1122 ...

Reviews: