Media Redundancy Protocol (MRP)
20
2.5 Example Configuration
UM RedundConfig RSPL
Release 2.0 02/2013
Note:
Configure all the devices of the MRP-Ring individually. Before you
connect the redundant line, you must have completed the configuration of all
the devices of the MRP-Ring. You thus avoid loops during the configuration
phase.
You deactivate the flow control on the participating ports.
If the flow control and the redundancy function are active at the same
time, there is a risk that the redundancy function will not operate as
intended. (Default setting: flow control deactivated globally and activated
on all ports.)
Switch Spanning Tree off on all devices in the network:
Open the
Redundancy:Spanning Tree:Global
dialog.
Switch off the function.
In the state on delivery, Spanning Tree is switched on on the device.
Figure 7: Switching the function off
enable
Switch to the privileged EXEC mode.
configure
Switch to the Configuration mode.
no spanning-tree operation
Switches Spanning Tree off.
show spanning-tree global
Displays the parameters for checking.