8
Installation RS20/22/30/32/40
Release 03 06/2013
ATEX directive 94/9/EG – specific regulations for safe
operation
Relevant for RS20/22/30/32/40 devices when operating in explosive gas
atmospheres according to ATEX Directive 94/9/EC, the following applies:
List of Standards:
EN 60079-0:2009
EN60079-15:2010
Certificate No.: DEKRA 11ATEX0139 X or KEMA 09ATEX0067 X.
Make sure that the device has the following label:
II 3G Ex nA IIC T4 Gc DEKRA
11ATEX0139
X
for RS20/22/30/32 types.
II 3G Ex nA IIC T3 ... T4 Gc
KEMA 09ATEX0067 X
for RS40 types.
Ambient rating and temperature code for RS20 and RS30 types:
T4: 0 °C
≤
Ta
≤
+60 °C for „S“ types
(item 14 of nomenclature
breakdown) or
T4:
−
40 °C
≤
Ta
≤
+70 °C for „T“ or „E“ types
(item 14 of
nomenclature breakdown).
Ambient rating and temperature code for RS22 and RS32 types:
T4:
−
40 °C
≤
Ta
≤
+50 °C for „T“ or „E“ types
(item 14 of
nomenclature breakdown) or
T4: 0 °C
≤
Ta
≤
+50 °C for „S“-Typen
(item 14 of nomenclature
breakdown)
Ambient rating and temperature code for RS40 types:
T3:
−
40 °C
≤
Ta
≤
+70 °C for „T“ or „E“ types
(item 14 of
nomenclature breakdown).
T4:
−
40 °C
≤
Ta
≤
+60 °C for „T“ or „E“ types
(item 14 of
nomenclature breakdown) or
T4: 0 °C
≤
Ta
≤
+60 °C for „S“ types
(item 14 of nomenclature
breakdown)
The modules shall be installed in a suitable enclosure in accordance
with EN 60079-15 providing a degree of protection of at least IP54
according to EN 60529, taking into account the environmental
conditions under which the equipment will be used.
Summary of Contents for Hirschmann RPS90/48V HV