32
Installation RSP20/25/30/35
Release 18 09/2021
1.6
Display elements
After the supply voltage is set up, the Software starts and initializes the
device. Afterwards, the device performs a self-test. During this process,
various LEDs light up.
1.6.1
Device state
These LEDs provide information about conditions which affect the operation
of the whole device.
Applies to software releases
before
02.0.00:
LED
Display
Color Activity
Meaning
Power Supply voltage
—
none
Supply voltage is too low
yellow lights up
Device variants with redundant power
supply:
Supply voltage 1
or
2 is on
flashes 4 times
a period
Software update is running. Maintain the
power supply.
green lights up
Device variants with redundant power
supply:
Supply voltage 1
and
2 is on
Device variants with single power supply:
Supply voltage is on
RM
Ring Manager
—
none
No redundancy configured
green lights up
Redundancy exists
flashes 1 time
a period
Device is reporting an incorrect
configuration of the RM function
yellow lights up
No redundancy exists
ACA
Storage medium
ACA31
—
none
ACA storage medium not connected
green lights up
ACA storage medium connected
flashes 3 times
a period
Device writes to/reads from the storage
medium
yellow lights up
ACA storage medium inoperative
LED
Display
Color Activity
Meaning
Status Device Status
—
none
Device is starting and/or is not ready for
operation.
green lights up
Device is ready for operation.
Characteristics can be configured
red
lights up
Device is inoperative
flashes 1 time
a period
The boot parameters used when the
device has been started differ from the
boot parameters saved.
Start the device again.
Status
RM
ACA
Power
Summary of Contents for HIRSCHMANN RSP20
Page 70: ......