Installation RSP20/25/30/35
Release 18 09/2021
55
Supply voltage
with the
characteristic
value K9 and KK
Rated voltage AC:
110 V AC ... 230 V AC, 50 Hz ... 60 Hz
Voltage range AC incl.
maximum tolerances:
88 V AC ... 265 V AC, 47 Hz ... 63 Hz
Rated voltage DC:
60 V DC ... 250 V DC
Voltage range DC incl.
maximum tolerances:
48 V DC ... 320 V DC
Connection type
3-pin terminal block
Tightening torque
4.5 lb-in (0.51 Nm)
Power loss buffer
>10 ms at 98 V AC
>10 ms at 51 V DC
Overload current
protection on the device
Non-replaceable fuse
Back-up fuse
Nominal rating:
Characteristic:
1 A ... 20 A
slow blow
Peak inrush current
<3.5 A
Climatic
conditions during
operation
Minimum clearance
around the device
Top and bottom device side: 3.94 in (10 cm)
Left and right device side: 0.79 in (2 cm)
Derating
a
:
refer to the Hirschmann product web page at
Ambient air temperature
b
Devices with operating temperature
characteristic value S (standard):
+32 °F ... +140 °F (0 °C ... +60 °C)
c
Devices with operating temperature
characteristic value E and T (extended):
−
40 °F ... +158 °F (
−
40 °C ... +70 °C)
de
-40 °F ... +185 °F (-40 °C ... +85 °C) for 16 hours
(tested in accordance with IEC 60068-2-2)
df
Maximum inner
temperature of device
(guideline)
Devices with operating temperature
characteristic value S (standard):
+86 °C
Devices with operating temperature
characteristic value E and T (extended):
+91 °C
Humidity
5 % ... 95 %
(non-condensing)
Air pressure
min. 700 hPa (+9842 ft; +3000 m)
max. 1060 hPa (-1312 ft; -400 m)
Summary of Contents for HIRSCHMANN RSP20