28
Installation SPIDER II
Release 07 10/2013
Dimension drawing
Figure 7: Dimensions of the SPIDER II
EMC and immunity
Protection classes Laser protection
Class 1 in compliance with IEC
60825-1
Degree of protection
IP 30
EMC compliance – IEC/EN 61000-6-2:2005 EMI
TYPE tests, test acc. to:
IEC/EN 61000-4-2 Electrostatic discharge
Contact discharge
Air discharge
SPIDER II 8TX/...
SPIDER II Giga/ ...
± 4 kV
± 6 kV
± 8 kV
IEC/EN 61000-4-3 Electromagnetic field
80 MHz ... 2700 MHz
20 V/m
IEC/EN 61000-4-4 Fast transients (burst)
DC power line
Data line
± 2 kV
± 4 kV
IEC/EN 61000-4-5 Voltage surges
DC power line, line / line
DC Power Line, line / ground
Data line, line / ground
SPIDER II without PoE
SPIDER II 8TX PoE
± 1 kV
± 2 KV
± 1 kV
± 2 KV
110,8
9,5
52,3
50,5
73,2
13,8
mm
inch
0.54
2.88
2.06
1.99
4.36
0.37