2.3
Connecting the terminal block for the
supply voltage and the grounding
A 3-pin terminal block is used for the grounding and for connecting the supply
voltage.
Note:
Relevant for North America:
The tightening torque of the terminal screws is max. 4.4 lb in. (0.5 Nm).
The torque for tightening the supply voltage terminal block on the device is
4.5 lb in (0.51 Nm).
Pull the terminal block off the device.
Connect the ground connection.
Connect the supply voltage lines.
2.4
Mounting the device on the DIN rail
CAUTION
ELECTRIC SHOCK
Solely connect a supply voltage that corresponds to the type plate of your
device.
Failure to follow these instructions can result in injury or equipment
damage.
Figure
Pin
Assignment
Voltage range DC
1
+24 V
9,6 V ... 32 V
SPIDER II 8TX PoE
18 V ... 32 V
2
0 V
3
Ground connection
Table 11: Pin assignment of the 3-pin terminal block for the supply voltage
CAUTION
TRANSIENT OR ELECTROSTATIC DISCHARGES
Do not open the housing.
Failure to follow these instructions can result in injury or equipment
damage.
1
2
3
+24 V
0 V