background image

THE 

SCIENCE

 

BEHIND HEAT

Instructions for Use

Before First Use

When using this PTC Tower Heater for the first time, a slight odour may be emitted. This is 
normal and will subside after a few uses. 
Place the PTC Heater on a flat, stable, heat-resistant in an open space, at least 120 cm away 
from furniture, walls, objects, curtains or any other flammable materials.  
Check that the air intake is not blocked.

Using the PTC Heater 

Position the PTC Tower Heater on a flat, stable, heat-resistant surface, at least 120 cm from 
walls, objects and furniture.  
Plug the PTC Tower Heater into the mains power supply. 
Turn on the ‘On/Off’ switch on the base of the PTC Tower Heater, then press the ‘On/Off’ 
button on the control panel. 
Press the ‘Fan’ button to operate the fan system. The PTC Tower Heater will blow out cold air. 
Select the desired heat setting using the heat setting switches. For a low heat setting, press one of 
the heat setting switches. For a high heat setting, press down both of the heat setting switches. 
To use the oscillation function, press the ‘Oscillation’ button. 
To turn off the PTC Tower Heater, switch off the ‘Fan’ button, both heat setting switches and 
the ‘On/Off’ button on the control panel. Switch off the ‘On/Off’ switch at the base of the PTC 
Tower Heater and then unplug the heater from the mains power supply.

Thermal Safety Cut-Out

This PTC Tower Heater is fitted with a thermal safety cut-out system, built-in to prevent it 
overheating. Should the PTC Tower Heater start to overheat, the thermal safety cut-out system 
will automatically operate and the PTC Tower Heater will switch off. The PTC Tower Heater 
will only resume normal operation when it has been manually switched back on. 
When the thermal safety cut-out activates, the PTC Tower Heater should be left to cool for 
approximately 30 minutes before using again. 
Before turning the PTC Tower Heater back on, check that there is nothing obstructing the 
airflow or blocking the air intake and that the PTC Tower Heater has been placed at least 120 
cm away from walls, objects and furniture.

EH0933 PTC Tower Heater

7

Summary of Contents for EH0933

Page 1: ...THE SCIENCE BEHIND HEAT PTCTower Heater Instruction Manual THE SCIENCE BEHIND HEAT www beldray com ...

Page 2: ...pliance or perform user maintenance Children should be supervised to ensure that they do not play with the appliance This appliance is not a toy This appliance contains no user serviceable parts If the power supply cord plug or any part of the appliance is malfunctioning or if it has been dropped or damaged only a qualified electrician should carry out repairs Improper repairs may place the user a...

Page 3: ...he appliance on automatically as there is a risk of fire if the heater is covered or positioned incorrectly Do not clean the appliance with abrasive chemicals or materials such as scourers as they may damage the appliance and impair future function The appliance should be used on a stable heat resistant surface The appliance must not be located immediately below or next to a mains power supply Alw...

Page 4: ... when not in use Warning In order to avoid a hazard due to inadvertent resetting of the thermal cut out this appliance must not be supplied through an external switching device such as a timer or connected to a circuit this is regularly switched on and off by the appliance Caution Some parts of this product can become very hot and cause burns Particular attention has to be given where children and...

Page 5: ...ruction manual Features 2000 W Two heat settings Cool air function Overheat protection Thermal cut out device Portable with carry handle Tip over switch Power indicator light Oscillation function Description of Parts EH0933 PTC Tower Heater 6 1 Main body 2 Control panel 3 Oscillation button 4 Heat setting switches 1000 W 5 Fan button 6 On Off button 7 Air intake 8 Carry handle 1 2 8 3 5 4 4 6 7 ...

Page 6: ...igh heat setting press down both of the heat setting switches To use the oscillation function press the Oscillation button To turn off the PTC Tower Heater switch off the Fan button both heat setting switches and the On Off button on the control panel Switch off the On Off switch at the base of the PTC Tower Heater and then unplug the heater from the mains power supply Thermal Safety Cut Out This ...

Page 7: ...ry thoroughly Do not use harsh or abrasive cleaning solvents as these may damage the finish of the PTC Tower Heater Do not immerse the PTC Tower Heater in water or any other liquid Storage Ensure that the PTC Tower Heater is completely cool Wrap the power supply cord loosely around the PTC Heater Store in a cool dry place Specifications Product code EH0933 Voltage 220 240 V 50 Hz Output 2000 W EH0...

Page 8: ...D On no account must either the BROWN or the BLUE wire be connected to the EARTH terminal Always ensure that the cord grip is fastened correctly The plug must be fitted with a fuse of the same rating already fitted and conforming to BS 1362 and be ASTA approved If in doubt consult a qualified electrician who will be pleased to do this for you Non rewireable mains plug If your appliance is supplied...

Page 9: ... for domestic purposes in accordance with the instructions and provided that it is not connected to an unsuitable electricity supply or dismantled or interfered with in any way or damaged through misuse Under this guarantee we undertake to repair or replace free of charge any parts found to be defective Reasonable proof of purchase must be provided Nothing in this guarantee or in the instructions ...

Page 10: ... Global Sourcing Victoria Street Manchester OL9 0DD UK 44 0 161 934 2240 customersupport beldray co uk Please retain all instructions for future reference Made in China CD270613 MD280414 V2 2014 Beldray Trademark All rights reserved ...

Reviews: