10
MAINTENANCE
DUST COLLECTOR HOUSING
Protection against corrosion is required in the form of periodic repainting.
FAN IMPELLER AND MOTOR REMOVAL - INSTALLATION
The fan motor is bolted to a motor support plate. The impeller is installed
directly on the motor shaft. Unbolt and remove the piping installed at the fan
inlet. Remove the impeller from the motor shaft. Unbolt and remove the
motor from the motor support plate. For installation, reverse the above.
INSPECTION TO TAKE PLACE AFTER THE FIRST WEEK OF OPERATION
-
Check the dust collector for filter bags failure and abrasion.
-
During the first week of operation, check the storage section for waste
level and determine the emptying frequency that will be required.
SEMI ANNUAL INSPECTION
-
Lubricate all electric motors, exhaust fans, etc., as per manufacturer's
instructions.
-
Check all filter bags for proper tension.
-
Check the dust collector for filter bags failure and abrasion.
Summary of Contents for NBM
Page 2: ......
Page 29: ...APPENDIX ANNEXE 1 RECOMMENDED SPARE PARTS LIST LISTE DE PIÈCES DE RECHANGE RECOMMENDÉES ...
Page 30: ......
Page 32: ......
Page 33: ...APPENDIX ANNEXE 2 DRAWINGS DESSINS ...
Page 34: ......