background image

4

 - FORM NO. 56041867 - SOLUS 500 B

INSPECTION:

Carefully unpack and inspect your SOLUS-500 for shipping damage.  Each machine is tested and inspected before shipping.  
Any shipping damage incurred is the responsibility of the carrier.  You should notify the carrier immediately if you notice dam-
age to the box or to the machine or parts.

CLEANING SOLUTIONS:

We recommend liquid cleaning chemicals.  Powder chemicals may be used, but unless mixed very thoroughly they could 
cause a build-up in the pump, lines, heat exchanger and/or quick disconnects.  Any problem caused by a chemical build-up is 
not covered by warranty.  Use a neutral cleaner with a pH between 5 and 10 to avoid premature wear of the pump, seals, and/
or other components.  Damage caused by the use of strong chemicals is not covered by the warranty.

MAINTENANCE:

For optimum performance 

fl

 ush the machine with clear water at the end of each working day.  Once a month, minimum, run 

fl

 ushing compound through the machine to break up any mineral or chemical build-up that may have formed.  The vacuum 

motor, pump motor, and the pump do not require any scheduled maintenance; however, the motors may require replacement 
brushes after 1000 - 1500 hours, and the pump and bypass valve may require rebuild kits after 1000 - 1500 hours, typically 
(refer to machine part list for numbers).  Clean the body with an all-purpose detergent, and protect it with an automobile inte-
rior polish.  Lubricate the wheels, castors, and quick disconnects with an all purpose silicone spray.

PARTS AND SERVICE:

Repairs, when required, should be performed by your authorized distributor who maintains an inventory of original replace-
ment parts and accessories.  Call the distributor from whom you purchased this machine if you need parts and service.  Be 
sure to specify the machine model.  Have your serial number handy.

SERIAL NUMBER: 

__________________

MODEL: SOLUS-500-B

PURCHASE DATE: 

__________________

NAME AND PHONE NUMBER OF YOUR DISTRIBUTOR: 

____________________________________________

____________________________________________

(Be sure to register your purchase to activate your warranty)

MODIFICATIONS

Modi

fi

 cations and additions to the cleaning machine which affect capacity and safe operation shall not be performed by the 

customer or user without prior written approval from the manufacturer. Unapproved modi

fi

 cations will void the machine warranty 

and make the customer liable for any resulting accidents.

Summary of Contents for SOLUS-500

Page 1: ...o prevent vacuum motor damage 2 Keep machine from rain and snow extremes in temperatures and store in a heated location DO NOT let the machine or the wand freeze Do not use outdoors 3 Do not let the pump run dry 4 Use approved chemicals only NO SOLVENTS 5 Wear gloves or use rags when removing quick disconnects to prevent burns 6 Never use water above 130 ºF 54 ºC in the solution tank revised 5 11 ...

Page 2: ...outdoors or dropped into water return it to a service center Do not pull by the cord use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Do not run the machine over the cord Keep the cord away from heated surfaces To unplug grasp the plug not the cord Do not handle the plug the cord or the machine with wet hands Extension cords must be 12 3 and no longe...

Page 3: ...enance however the motors may require replacement brushes after 1000 1500 hours and the pump and bypass valve may require rebuild kits after 1000 1500 hours typically refer to machine part list for numbers Clean the body with an all purpose detergent and protect it with an automobile inte rior polish Lubricate the wheels castors and quick disconnects with an all purpose silicone spray PARTS AND SE...

Page 4: ...ce this hose into a drain and use clean water to rinse out the dirt and debris from the tank NOTE be sure to close the cap tightly before using the machine again HANDLES The handles are used to move the machine These handles allow you to tilt the machine back onto its 12 wheels for easy maneuvering and or for moving on stairways SWITCH PLATE The switches are located on the rear of the machine out ...

Page 5: ... The pump spraying pressure will be observable at the pressure gauge VACUUM SWITCH 4 This switch will illuminate when the vacuum motors are on The vacuum motors run off of cord 1 CIRCUIT LOCATOR 5 When this light is on it indicates that cord 2 Identified by the red H on the back of the extractor is on a separate line from cord 1 Cord 2 supplies voltage to the heater allowing it to heat to the temp...

Page 6: ...the tanks as necessary 9 When finished with the job vacuum all unused solution into the recovery tank and dump the tank Clean the tanks and filters Clean the tool and hoses Store the machine in a heated location ELECTRIC CIRCUIT LOCATOR This unique patented smart system operated by a solid state circuit will inform the operator when the two cords are plugged into separate lines by illuminating the...

Page 7: ... 25 18 26 28 31 45 36 37 40 38 46 55 57 56 58 62 60 64 66 67 68 53 52 73 70 72 51 50 49 1 5 3 3A 7 6 5A 6A 29 28A 31 24 12 16 18 15 14 19 20 22 19 13 17 11 10 75 74 71 77 PUMP 9 26 34 63 54 44 42 41 43 65 15A 9A 13A 23 Pump inlet hose Pump bypass hose 69 78 81 82 83 ...

Page 8: ...3 8 Brass 1 Reducer 3 8 Pipe Female 2 Bushing 3 8 X 1 4 Pipe Brass 1 Elbow 90 Deg 1 4 Mpt X 1 4 1 Plug Brass Pipe 1 4 Pipe 1 Unloader Valve For 500 PSI 54 FP542 1 Hose assembly pump to gauge 1 Hose Pulsation Dampening 28 1 Quick Connect Brass 1 4 FPT 1 Nipple 1 4 Pipe Brass 55 801D 2 Hinge pin 4 75 56 27A 2 Axle Cap 57 2092 2 Wheel 12 58 910 2375 1 Axle rod 60 1 Base NOTE 1 62 905 2 Castor 4 63 21...

Page 9: ...too long Try spraying for 12 15 seconds or about three strokes Heat exchanger needs to be flushed Wrong tool being used Too much water passing through Longer hose or larger diameter hose than standard NO HEAT Heat is not turned on Either the green light must be on or the bypass switch must be turned on No power in the wall outlet check to see if the breaker has tripped No power to the bypass switc...

Page 10: ...NOTES SOLUS 500 EXTRACTOR 120V ...