background image

Software Installation (Installation Optional) 

A) 

To fully utilize the UPS and its software, your computer 

must be able to operate the following operating systems: 

Windows98/ ME/ NT4/ 2000 / 2003/ XP and have a USB 

port. 

B) 

Your UPS features the Bulldog Plus Shutdown Software. 

This allows you   to protect and save your data should a 

power outage occur, as well as safely shutdown your 

computer in your absence. Please be sure to close out of 

all applications prior to installing the software. 

1.  To install the software, please place the CD into the CD 

drive of your computer. 

2.  Your computer should autorun the CD. If this does not 

occur, go to the Run feature on your Start icon (lower left 

corner) on your screen. Please enter the CD drive, it may 

be D: Upon entering the drive run setup.exe. to execute 

the software. Should you continue to have a problem, 

please refer to your computer’s owner’s manual for the 

correct drive.   

3.  The “Welcome to the Belkin Bulldog Plus Product 

Installation Browser” will appear. Please click Install and 

select the Windows version. 

4.  The Bulldog Plus Installation window will appear. Please 

choose the appropriate software to install. 

5.  Install Shield Wizard will appear onscreen, click Next. 
6.  Please read the License Agreement and click Yes. 

On Setup Type, ALL (Standalone) is the default. 

Standalone is for UPS management for your computer 

only. Networking management is for administrators who 

need to manage several UPSes in a workstation 

environment. You should not install the networking files 

unless you are technically qualified to use these features. 

For more information on networking, please refer to the 

software user’s manual.   

8.  On Choose Destination Folder, you have the option to 

choose the location of where you would like the Software 

located on your computer.    We recommend using the 

default option as shown on screen. To use the default 

option, click Next. 

9.  On Select Program Folder, you have the option to 

choose the program folder for your Software. We 

recommend using the default option as shown on screen. 

To use the default option, click Next. 

10.  On the Select Language screen, please select your 

language choice. 

11.  The software will now be installed. Once completed, 

please click Finish. 

Note! 

Please refer to the help feature found on the Belkin On-line 

Screen. To access this screen, please click the Belkin shield 

found in the lower right corner on your task bar of your 

screen.   

Once the Belkin On-line screen appears, choose help. The 

Bulldog Online Help screen will appear. You may use the 

Contents, Index or Search tabs to assist you with your help 

issues and to get more information on the specific features 

and functions of the software. 

C) User Manual Installation 

You will need Adobe Acrobat Reader to review the User’s 

Manuals. If you do not have the reader, please goto 

www.adobe.com to download a free version of the software. 
1.  From the “Welcome to the Belkin Bulldog Plus Product 

Installation Browser” window, locate and choose User 

Manual’s. 

2.  The “Bulldog Plus User Manuals” window will appear. 

Please move your pointer to the manual you wish to 

open and click. 

3.  An Adobe PDF file will be opened. To save a copy to 

your hard drive, you will need to goto “File” on your menu 

bar and choose “Save a copy”. 

4.  On the Save a Copy window, please choose a 

destination folder for the manual.   

D) Uninstall for Windows 98/ Me/ NT4/ 2000 / 2003/ XP 

There are two options to uninstall the Belkin Shutdown 

Software. 

Option 1 

1.  Click the Start icon in the lower left hand corner of your 

screen and goto the Programs folder. Scroll to the Belkin 

Bulldog Plus folder and choose setup.    Install Wizard 

will appear.   

2.  Choose Remove and click Next.   
3.  The Program Files and Audio Files will be checked. If 

they are not, please check them. Click Next. The 

uninstall procedure will begin. 

4.  Click Finish when complete. 

Option 2   

(Note: Windows2000/ 2003/ XP users choose the 

Control panel function from your Start icon and then 

goto to step 2.) 

1. 

Click the Start icon in the lower left hand corner of your 

screen and goto the Settings icon. Goto and choose 

the Control Panel folder. The Control Panel window will 

appear.  

2. 

Locate and click the Add/Remove Programs icon. The 

Add/Remove Programs window will appear. 

3.  Locate and choose the Belkin Bulldog Plus software. 

Click the Change/Remove button on the right. Install 

Wizard will appear.   

4. 

Choose Remove and click Next.   

5.  The Program Files & Audio Files will be checked. If 

they are not, please check them. Click Next. The 

uninstall procedure will begin. 

6. 

Click Finish when complete. 

 

 
 

                     TECHNICAL SPECIFICATIONS                   

 

MODEL 

F6C550- 

AVR 

F6C750- 

AVR 

F6B750- 

AVR 

Capacity 

550VA / 

330W

750VA / 400W 

Voltage Range

90-136Vac 

INPUT 

 Frequency   

60HZ ( 

±

3HZ ) 

Voltage 

Simulated sine wave, 120vac

±

10% 

OUTPUT 

Frequency 

(On battery) 

60HZ ( 

±

1HZ ) 

Back up time

Full / half load

2-8 

 mins

1.5-5 

mins 

1.5-5 

mins 

BATTERY 

Typical 

Recharge Time

  12hours recover 85% 

capacity 

ENVIRONMENT

Ambient 

operation  

0~85% humidity 

non-condensing, 0~35

 

Safety 

UL / c-UL, FCC class B 

CONFORMANCE

Surge 

IEEE C62.41 Category A 

standard 

Dimension 

(W X H X D)

4.57 x 8.98 x 12.95 inches 

(116 x 228 x 329 mm) 

PHYSICAL 

Net weight 

6.6kgs/ 

14.52lbs 

7.1kgs/  

15.62lbs 

All specifications are subject to change without prior notice. 

                                                                STORAGE                                                         

                                                                                 

Storage Conditions 

Store the UPS covered and upright in a cool, dry location with its 
battery fully charged. Before storing, charge the UPS for at least 
four hours. Disconnect any cables connected to the computer 
interface port to avoid unnecessary drainage of the battery. 

Extended Storage 

During extended storage in environments where the ambient 
temperature is +5

 o

F to +86

 o

F, charge the UPS battery every six 

months. During extended storage in environments where the 
ambient temperature is +86

 o

F to +113

 o

F, charge the UPS battery 

every three months. 

Note:

 

 

 

 
              BELKIN COMPONENTS USER LICENSE AGREEMENT                           

                                                     

Belkin Components (Belkin”) thanks you for choosing one of our 
products. This User License Agreement (Agreement”) contains the 
terms and conditions under which limited use of the product is 
licensed to you. 
PLEASE READ THIS NOTICE CAREFULLY. DO NOT USE THE 
SOFTWARE OR PRODUCT UNTIL YOU HAVE READ AND 
AGREED TO THIS AGREEMENT. IF YOU USE THE SOFTWARE 
AND PRODUCT, YOU ARE AGREEING TO THE TERMS AND 
CONDITIONS SET OUT IN   
THIS AGREEMENT. IF YOU DO NOT ACCEPT THESE TERMS 
AND CONDITIONS, YOU MUST RETURN THE UNOPENED 
PRODUCT WITH THE DISKS INSIDE TO THE PARTY FROM 
WHOM YOU RECEIVED IT.   

SCOPE OF USE: 

In this Agreement, software means all 

machine-readable software programs and associated files in this 
package. All modified versions of and upgrades or improvements to 
such programs and all copies of such programs and files. You, a 
single user opening this envelope (You or our), may use the 
software on a single central processing unit. You may not rent it, 
loan it out, or lease it, nor use it on a multi-user system. 

LICENSE: 

You have the non-exclusive right to use the software. 

You are not permitted to copy, modify or transfer the software or 
documentation. You may not compile, disassemble or otherwise 
reverse engineer, breakdown, analyze or modify the software. 

USE AND RESTRICTIONS: 

You are permitted to make backup 

copies of all the software disks for archival purposes only. You must 
reproduce the proprietary notice set forth on the disks and affix 
them to all backup copies. You are not permitted to use these 
programs in connection with a computer service, or to use the 
backup copies other than as a replacement for the original copy. 

TERM:

 This license is effective upon acceptance by opening this 

envelope or in any other way using the enclosed software, which will 
constitute your acceptance of, and agreement to, this Agreement, 
and is effective until terminated. The limited license in this 
Agreement will be automatically terminated if you fail to comply with 
any of the Terms and conditions in this Agreement. You agree that 
upon such termination you will immediately destroy all programs and 
documentation, including all copies made or obtained by you. 
SOFTWARE, PROGRAM, DOCUMENTATION, AND ANY 
RELATED INFORMATION, GOODS OR SERVICES ARE 
PROVIDED WITH NO WARRANTY OR REPRESENTATION OF 
ANY KIND WHAT SO EVER. BELKIN HEREBY DISCLAIMS ALL 
OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING 
BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF 
MERCHANTABILITY AND FITNESS FOR A PARTICULAR 
PURPOSE.   
The entire risk of the use, results and performance of the software, 
program and documentation is borne by you. Should any or all of the 
product, software, program, documentation, or related information, 
goods or services be defective, misused, unsuitable or cause or give 
rise to any harm or liability whatsoever, you, not Belkin or its 
associates, dealers or agents, assume the entire liability, cost of 
repair, correction or any payment or other remedy whatsoever.   
Furthermore, no warranty or guarantee is made regarding the use or 
results of the product, software, program, documentation, or any 
related information, goods or services in terms of correctness, 
accuracy, reliability, timeliness or otherwise.    You use and rely on 

the program at your own risk. The following is the only and 
exclusive warranty and remedy of any kind: Belkin does 
warrant that the program disks are free from physical defects in 
materials and workmanship under normal use for a period of 
one (1) year from the date of purchase, as evidenced by a copy 
of the sales receipt.    Return the defective disk or 
documentation with your receipt directly to Belkin for a 
replacement.   

DISCLAIMER: 

Belkin or its associates will in no event be 

liable (i) in any amount for lost profits or special, incidental, 
punitive or consequential damages, or (ii) for any claim or 
damage of any nature, or under any theory, whatsoever, in 
any amount in excess of the purchase price you paid for the 
product. The warranties and remedies here set forth are 
exclusive, and in lieu of all others oral or written, express or 
implied. Some jurisdictions do not allow exclusion or limitation 
of implied warranties or of liability for incidental damages, so 
the foregoing limitations or exclusion may not apply to you. 
This warranty gives you specific legal rights, which vary from 
jurisdiction to jurisdiction.   
HOWEVER, YOU WAIVE SUCH RIGHTS, EXCEPT AS 
EXPRESSLY PROVIDED UNDER THE TERMS AND 
CONDITIONS OF THIS AGREEMENT, TO THE MAXIMUM 
EXTENT ALLOWED BY LAW. 
The license is governed by the laws prevailing in the State of 
New York, without regard to its conflicts of laws principles.

 

ACKNOWLEDGMENT:   

By opening the package on which this Agreement is printed, 
or through which it is visible, you acknowledge that you have 
read this Agreement, understand it, and agree that this 
agreement is the complete and exclusive statement of 
agreement between yourself and Belkin and supersedes any 
prior agreements, oral or written, and any other 
communications relating to the subject matter of this 
Agreement. 

SEVERABILITY:  

Any term or provision of this Agreement or any application 
thereof, which may be prohibited or unenforceable by law in a 
particular jurisdiction, shall be interpreted and enforced to the 
maximum extent allowed in such jurisdiction (which the parties 
acknowledge could mean severing the provision from this 
Agreement or, if allowed, enforcing it in a narrower form), 
without affecting the remainder of this Agreement, or any 
other application of such term or provision in such jurisdiction, 
or application of such term or provision in any jurisdiction. 

                                    SAFETY INFORMATION                                         

CAUTION! 

 

Internal battery voltage is 12V DC. 

 

The unit is intended for installation in a controlled 

environment (temperature controlled, indoor area free of 

conductive contaminants). 

 

All batteries used are Sealed Lead Batteries. Batteries must 

be recycled. 

Recycling Information 

Your UPS contains a Non-spillable Sealed Lead Battery. On 
the battery, you will find the battery name. Please reference 
the chart below for recycling information. 

Battery Name 

Recycling 
Inside the 
USA 

Recycling Outside 
the USA 

BB Battery   

(800) 278-8599

N/A 

CSB Battery 

(800) 738-7372

1 (817) 244-4415 

VISION Battery 

(973) 726-5323  N/A 

RITAR Battery   

(888) 841-5179

N/A 

 

TROUBLE SHOOTING 

PROBLEM

POSSIBLE CAUSE 

SOLUTION 

On/ Off /Test button 

not pushed or pushed 

less than 2 second 

Press the On/Off 

/Test button for more 

than 2 seconds 

Battery voltage is too 

low 

Recharge the UPS at 

least eight hours 

UPS not on, 

LED not lit 

UPS fault 

Contact service 

personnel 

Power cord loose   

Re-plug the power 

cord  

AC breaker is burned 

out or tripped 

Replace or reset the 

breaker  

UPS always 

on battery 

mode 

Ac utility voltage is too 

high or too low, or 

black out 

Normal condition 

Battery not fully 

charged 

Recharge the UPS at 

least eight hours 

UPS is overload 

Remove some 

un-necessary loads 

Back up time 

too short 

Charger fault or other 

reason 

Replace battery.   

Contact belkin.com 

The UPS 

continuously 

beeps 

Overload 

Remove the 

non-critical loads   

Red LED lit 

Battery failure 

Replace battery. 

Contact belkin.com 

                                          CONTACT US                                         

Belkin Components, Ltd 

501 West Walnut St.   

Compton, CA • 90220-5221 USA

Tel: 310.898.1100 

Fax: 310.898.1111 

Belkin Components, Ltd   

Unit 13 • Gatelodge Close • 

Round Spinney   

Northampton, NN3 8RX UK 

Tel: +44 (0) 1604678300 • 

Fax: +44 (0) 1604678330 

Belkin Components B.V. 

Starparc Building Boeing 

Avenue 3331119 PH 

Schiphol-Rijk The Netherlands   

Tel: +31 (0) 20 654 73 00   

Fax: +31 (0) 20 654 73 49 

Belkin Australia Ltd 

7 Bowen Cresent   

West Gosford, NSW 2250 

Tel: +61 (02) 4325 4666 

Fax: +61 (02) 4325 4277 

 

Please visit 

www.Belkin.com

 for battery replacement information. 

Away from sunlight   Away from heat    Away from

Reviews: