background image

Safety

5

CAUTION!

•  To reduce the risk of electric shock, disconnect the UPS from the main power supply before

installing a computer interface signal cable. Reconnect the power cord only after signaling
interconnections have been made. 

• The internal energy source (the battery) cannot be de-energised by the user. The output may

be energised when the unit is not connected to a main power supply, thus a shock hazard may
be present.

Electrical Safety

• Check that the power cord(s), plug(s), and sockets are in good condition.

• To reduce the risk of electric shock when grounding cannot be verified, disconnect the

equipment from the AC power outlet before installing or connecting to other equipment.
Reconnect the power cord only after all connections are made.

• Do not handle any kind of metallic connector before the power has been removed.

• Use one hand, whenever, possible to connect or disconnect signal cables to avoid a possible

shock from touching two surfaces with different electrical grounds.

• Connect the equipment to a three wire AC outlet (two poles plus ground). The receptacle

must be connected to an appropriate circuit protection device (fuse or circuit) breaker.
Connection to any other type of receptacle may result in a shock hazard.

WARNING: (RISK OF ELECTRIC SHOCK)
HAZARDOUS LIVE PARTS INSIDE THIS UNIT ARE energised FROM THE BATTERY
SUPPLY EVEN WHEN THE INPUT AC POWER IS NOT CONNECTED.

WARNING: (RISK OF ELECTRIC SHOCK)
DO NOT REMOVE COVER. NO USER SERVICEABLE PARTS INSIDE, PLEASE REFER
SERVICING TO QUALIFIED SERVICE PERSONNEL.

• One Belkin Regulator Pro Gold Series UPS (325VA, 425VA, 525VA, 625VA)

• One AC Power Cable 1.8M (6ft)

• One Telephone Cable 1.8M (6ft) RJ11(425VA, 525VA, 625VA Models Only)

• One Serial Cable RS232 1.8M (6ft) (425VA, 525VA, 625VA Models Only)

• One Cable Management Rail

• One Product Manual

• One Belkin Sentry Bulldog Shutdown Management Software CD 

(425VA, 525VA, 625VA Models Only)

• One Sticker (6 Languages)

• One Product/Connected Equipment/Data Recovery Warranty Sheet.

Contents List

En

P73220uk_Gold_UPSMan  27-05-2002  15:01  Page 5

Summary of Contents for F6C325-220V

Page 1: ...En P73220uk UPS Uninterruptible Power Supply User Manual P73220uk_Gold_UPSMan 27 05 2002 15 01 Page 1...

Page 2: ...the proper operation of the UPS come into question Please save or recycle the packaging materials The UPS shipping materials were designed with great care to provide protection from transportation re...

Page 3: ...nt Panel 6 Rear Panel 7 5 Installation 9 6 Operation 10 7 Alarm 11 8 Software Options 11 9 USB Interface Port 12 10 RS232 Interface Port 14 11 Battery Replacement 15 12 Troubleshooting 17 13 Storage 1...

Page 4: ...incur computer repairs lost data and downtime Solution A Belkin Uninterruptible Power Supply UPS with Automatic Voltage Regulation AVR Typical Stand by UPS units do not have AVR to increase the output...

Page 5: ...ible shock from touching two surfaces with different electrical grounds Connect the equipment to a three wire AC outlet two poles plus ground The receptacle must be connected to an appropriate circuit...

Page 6: ...s Battery output is drawing more power than the UPS can provide 4 3 REPLACE BATTERY Red Battery is too weak or bad If UPS is in On Battery mode this means the UPS is just testing the condition of the...

Page 7: ...sential equipment and reset the circuit breaker 4 10 BATTERY BACK UP OUTLETS Data sensitive equipment such as a computer monitor and external drive should be powered by these outlets Battery power is...

Page 8: ...tery Back up outlets 4 5 Interface Port USB or RS232 Depending on model 4 6 Telephone Fax Modem or 10 base T network Protection 4 7 Battery Replacement Door 4 9 AC Breaker Circuit Breaker 4 8 AC Input...

Page 9: ...Belkin Components for details of a local reseller 5 4 Connect Computer Interface Belkin Sentry Bulldog Shutdown Management Software and the USB or RS232 cable depending on model can be used with this...

Page 10: ...on when the UPS is supplying power to the connected loads The UPS can be utilised as a master on off switch for the protected equipment NOTE The UPS maintains the battery charge when in the off positi...

Page 11: ...Belkin Sentry Bulldog Shutdown Management Software or as stated in step 6 3 The alarm stops when the UPS returns to line normal operation 7 1 LOW BATTERY rapid alarm In backup mode when the battery en...

Page 12: ...up procedure Charge the UPS 2 4hours before installing the software Connect the supplied RS232 serial cable excluding 325VA Series to the UPS and connect the other end to a designated port on the PC T...

Page 13: ...n For Alarm 10 Voltage Sensitivity To Improve Transfer Time and Avoid Effect Of I P Distortion 11 Outlet Relay ON OFF Set Delay Time to Control Outlet Relay On Off 12 Next Shutdown Time To Next Schedu...

Page 14: ...condition 3 Monitoring inverter status 4 Monitoring UPS status 5 Monitoring the utility status 6 Providing the power switch function for the computer to turn on off the utility on schedule To save po...

Page 15: ...e battery compartment cover down Diagram b 11 1 3 Grasp the battery and slide it partially out Then grab the battery firmly and remove the battery wires will disconnect as the battery is pulled out Di...

Page 16: ...contact Belkin Components Diagram a Diagram b Slide the battery compartment cover Diagram d Slide the battery back in Avoid pinching the wires Diagram c Slide the battery partially out Diagram e Slid...

Page 17: ...g the power cord Replace the breaker Normal condition Recharge the UPS at least 4 hours Remove some unnecessary loads Replace battery Remove the non critical loads Replace battery 13 0 Storage Conditi...

Page 18: ...ad Type Protection Automatic self test and discharge protection replace battery indicator Typical Recharge Time 4 hours to 90 of full capacity Sealed maintenance free lead acid BATTERY PHYSICAL ALARM...

Page 19: ...load Type Protection Automatic self test and discharge protection replace battery indicator Typical Recharge Time 4 hours to 90 of full capacity Sealed maintenance free lead acid BATTERY PHYSICAL ALAR...

Page 20: ...SET FORTH ABOVE ARE EXCLUSIVE IN LIEU OF ALL OTHERS WHETHER ORAL OR WRITTEN EXPRESSED OR IMPLIED BELKIN SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES O...

Reviews: