background image

Troubleshooting

Power Conditioner is not providing power.

   

Check to ensure that the Power Conditioner is plugged into a properly 
grounded AC wall outlet. Some outlets require a wall switch to be turned on 
in order to deliver power to the outlet.

   

Too many devices may be plugged into the Power Conditioner, overloading 
the unit and tripping the overload circuit breaker. The Power Conditioner 
is not designed to handle current loads larger than 15 Amps or 1800 watts. 
Try unplugging some devices and resetting the circuit breaker (see below) 
located on the end of the Power Conditioner.

   

To reset the circuit breaker: Wait at least 10 minutes after the circuit breaker 
was tripped before attempting to reset the breaker. Press in the button 
located next to the power cord on the end of the unit to reset. Power should 
be restored to the outlets on the Power Conditioner.

   

Your components may be plugged into a “Switched” outlet and the outlets 
are not switched on. Check to ensure that the green “Switched On” light on 
the top of the Power Conditioner is illuminated. If the light is not illuminated, 
press the “Switched” button on top of the Power Conditioner unit until the 
light is illuminated. You should now have power to all of the switched outlets.

“Protecting” light is not lit.

   

Check to make sure that the Power Conditioner is plugged into a grounded 
AC wall outlet. The “PureFilter” light should be lit.

   

If the “Protecting” light is still not lit, the surge protection components 
in the Power Conditioner may be expired or damaged. Please call Belkin 
Corporation for a free replacement.

“Ground Fault” light is lit.

   

If the red “Ground Fault” light is lit, this indicates that your Power 
Conditioner is not plugged into a properly grounded AC outlet. Check 
to make sure that the Power Conditioner is plugged into a grounded AC 
wall outlet (3-prong AC outlets only. Do not use 2–3-prong adapters). The 
“PureFilter” light and the “Protecting” light should be lit.

   

If the “Ground Fault” light is still lit, you have a ground-wiring problem 
and you should contact an electrician to properly ground the outlet. 
Connecting the PureAV Power Conditioner to an improperly grounded outlet 
is not safe and will void all Belkin Corporation warranties. If the outlet is 
properly grounded and the “Ground Fault” light is still lit, please call Belkin 
Corporation for assistance.

For all other technical questions or troubleshooting issues, please contact 

Belkin Customer Service at 800-223-5546.

Pur
eA

V P
ow

er C
onditioner

12

ž

Summary of Contents for P74521-B

Page 1: ...AP11000 10 AP11200 12 AP11201 12 Home Theater Power Conditioner PF30L PF31L and PF40L User Manual...

Page 2: ...tched 7 Step 3 Connect Video Components to the Video Filter always on 7 Step 4 Connect Digital Components to the Digital Filter always on 8 Step 5 Connect your Pay Per View Phone Line 9 Step 6 Connect...

Page 3: ...sources within your home including digital components and household appliances Optimized to remove electrical noise Advanced PureFilterTM circuitry provides clean and clear power to all of your valuab...

Page 4: ...king properly 5 Ground Fault light Lights to indicate that the Power Conditioner is NOT plugged into a properly grounded outlet 6 HiCurrentTM Filter Delivers high current to power hungry amplifiers an...

Page 5: ...electrical disturbances that can travel down your coaxial cable lines 12 Broadband Ethernet Input Output PF31L PF40L only Protects broadband Ethernet lines used for digital media receivers gaming or b...

Page 6: ...is built to withstand large power surges we cannot guarantee that it will protect all of your equipment in the event of a large lightning storm In the event of a lightning storm it is best to unplug...

Page 7: ...bracket Fig A by aligning the mounting holes on the back of the Power Conditioner Fig C with the mounting screws on the surface of the wall mount bracket Fig B For mounting to a drywall surface 1 Use...

Page 8: ...audio equipment you may have PF30L PF31L only F Amp Connect your main amplifier power cord to the outlet labeled High Current AMP This outlet is specifically designed to deliver high current to power...

Page 9: ...the cord into the corresponding outlet on the Power Conditioner B Cable Satellite Connect your cable or satellite receiver power cord to the outlet labeled Cable SAT C Digital Video Recorder Connect...

Page 10: ...our telephone cable to the Power Conditioner phone jack labeled IN B Connect one end of the PureAV phone cable included to the Power Conditioner phone jack labeled OUT Connect the other end of this ca...

Page 11: ...ect the other end of this cable to your cable TV tuner B Satellite DSS TV Connect the incoming satellite television coaxial cable line to the connector labeled SAT IN Connect one end of a second coaxi...

Page 12: ...C Control PF31L and PF40L only Your new Power Conditioner is equipped with a Remote AC DC Control jack remote trigger This allows you to power on and off the switched outlets on your Power Conditioner...

Page 13: ...ditioner unit until the light is illuminated You should now have power to all of the switched outlets Protecting light is not lit Check to make sure that the Power Conditioner is plugged into a ground...

Page 14: ...ation will repair or replace at its option any equipment which is damaged by a transient voltage surge spike or lightning strike an Occurrence while properly connected through a Belkin Power Condition...

Page 15: ...14...

Page 16: ...00 31 0 20 654 7349 fax Belkin Ltd Express Business Park Shipton Way Rushden NN10 6GL United Kingdom 44 0 1933 35 2000 44 0 1933 31 2000 fax Belkin Ltd 7 Bowen Crescent West Gosford NSW 2250 Australia...

Reviews: