Safety Precautions

Warning – Grounding and Polarization

This product must be plugged directly into a grounded AC power outlet (3-
prong). Do not use a 3-to-2-prong adapter to defeat the grounding pin. Do not 
plug or “daisy-chain” this product into other electrical products such as surge 
protectors, power strips, or UPSes. Do not plug this product into an extension 
cord. Failure to plug this product directly into a grounded outlet may result in 
personal injury or damage to your equipment. 
Call a licensed electrician if you are unsure that your AC outlets are 
properly grounded.

Warning – Rooftop Antennas and Satellite Dishes

If you use rooftop antennas, satellite dishes, or any other rooftop hardware that 
connects to your PureAV Power Conditioner, make sure the wires are properly 
grounded. This will protect against voltage surges from lightning strikes or 
static charges.

Warning – Lightning Storm Protection

Although your PureAV Power Conditioner is built to withstand large power 
surges, we cannot guarantee that it will protect all of your equipment in the 
event of a large lightning storm. In the event of a lightning storm, it is best to 
unplug your Power Conditioner from the wall. Once you have done this, there is 
no need to unplug any of the equipment that is connected to the 
Power Conditioner.

Warning – Water and other Liquids

Do not use this product with aquariums or other water-related products. Use 
indoors and in dry locations only. Do not operate the Power Conditioner if any 
liquid is spilled on or in the unit. Failure to follow these guidelines could result 
in serious bodily injury or death.

Warning – Cleaning

Always unplug the Power Conditioner before cleaning. It is only necessary to 
clean the Power Conditioner with a clean, dry cloth or duster. Do not use any 
cleaning solutions, sprays, or water.

Warning – No User-Serviceable Parts Inside

If, for any reason, your Power Conditioner is malfunctioning, do not attempt to 
repair or dismantle the unit in any way. Unplug the unit and consult this User 
Manual for warranty and service contact information.

Pur
eA

V P
ow

er C
onditioner

5

Summary of Contents for P74521-B

Page 1: ...AP11000 10 AP11200 12 AP11201 12 Home Theater Power Conditioner PF30L PF31L and PF40L User Manual...

Page 2: ...tched 7 Step 3 Connect Video Components to the Video Filter always on 7 Step 4 Connect Digital Components to the Digital Filter always on 8 Step 5 Connect your Pay Per View Phone Line 9 Step 6 Connect...

Page 3: ...sources within your home including digital components and household appliances Optimized to remove electrical noise Advanced PureFilterTM circuitry provides clean and clear power to all of your valuab...

Page 4: ...king properly 5 Ground Fault light Lights to indicate that the Power Conditioner is NOT plugged into a properly grounded outlet 6 HiCurrentTM Filter Delivers high current to power hungry amplifiers an...

Page 5: ...electrical disturbances that can travel down your coaxial cable lines 12 Broadband Ethernet Input Output PF31L PF40L only Protects broadband Ethernet lines used for digital media receivers gaming or b...

Page 6: ...is built to withstand large power surges we cannot guarantee that it will protect all of your equipment in the event of a large lightning storm In the event of a lightning storm it is best to unplug...

Page 7: ...bracket Fig A by aligning the mounting holes on the back of the Power Conditioner Fig C with the mounting screws on the surface of the wall mount bracket Fig B For mounting to a drywall surface 1 Use...

Page 8: ...audio equipment you may have PF30L PF31L only F Amp Connect your main amplifier power cord to the outlet labeled High Current AMP This outlet is specifically designed to deliver high current to power...

Page 9: ...the cord into the corresponding outlet on the Power Conditioner B Cable Satellite Connect your cable or satellite receiver power cord to the outlet labeled Cable SAT C Digital Video Recorder Connect...

Page 10: ...our telephone cable to the Power Conditioner phone jack labeled IN B Connect one end of the PureAV phone cable included to the Power Conditioner phone jack labeled OUT Connect the other end of this ca...

Page 11: ...ect the other end of this cable to your cable TV tuner B Satellite DSS TV Connect the incoming satellite television coaxial cable line to the connector labeled SAT IN Connect one end of a second coaxi...

Page 12: ...C Control PF31L and PF40L only Your new Power Conditioner is equipped with a Remote AC DC Control jack remote trigger This allows you to power on and off the switched outlets on your Power Conditioner...

Page 13: ...ditioner unit until the light is illuminated You should now have power to all of the switched outlets Protecting light is not lit Check to make sure that the Power Conditioner is plugged into a ground...

Page 14: ...ation will repair or replace at its option any equipment which is damaged by a transient voltage surge spike or lightning strike an Occurrence while properly connected through a Belkin Power Condition...

Page 15: ...14...

Page 16: ...00 31 0 20 654 7349 fax Belkin Ltd Express Business Park Shipton Way Rushden NN10 6GL United Kingdom 44 0 1933 35 2000 44 0 1933 31 2000 fax Belkin Ltd 7 Bowen Crescent West Gosford NSW 2250 Australia...

Reviews: