Events and Action Routines
178
Table 14-1. Authentication Failure Codes
Code
Description
Code
Description
0010
Invalid User ID
0050
Invalid password #1
0011
Blocked user
0053
Call Back unsuccessful
0012
Wrong time
0054
Invalid password #2
0032
Invalid ASG Key response
14.3.2 .BAT48HIGH Internal Event
The .BAT48HIGH event occurs when the 48V battery being monitored crosses over from an OK
threshold to a high voltage threshold. These thresholds are set using the Set Sensor Alarms
(SSA) command (see Section 10.7).
Alarm/Event
Action Routine
Parameters
Comments
.BAT48HIGH
SCHEDULE
15 PHONHOME
This example activates a call to the maintenance reporting center 15 minutes after the
.BAT46HIGH condition occurs.
14.3.3 .BAT48LOW Internal Event
The .BAT48LOW event occurs when the battery being monitored crosses over from an OK
threshold to a low voltage threshold. These thresholds are set using the Set Sensor Alarms
(SSA) command (see Section 10.7).
Example:
Alarm/Event
Action Routine
Parameters
Comments
.BAT48LOW
SCHEDULE
15 PHONHOME
In this example, the maintenance center is called 15 minutes after the .BAT48LOW condition
occurs.
Summary of Contents for Lucent Technologies Access Security Gateway Guard
Page 12: ...x Page intentionally left blank ...
Page 28: ...ASG Guard Overview 16 Page intentionally left blank ...
Page 36: ...Physical Connections 24 Page intentionally left blank ...
Page 60: ...Modem Port Setup 48 Page intentionally left blank ...
Page 82: ...Modifying the User Database 70 Page intentionally left blank ...
Page 120: ...Action and Event Tables 108 Page intentionally left blank ...
Page 158: ...User Connectivity 146 Page intentionally left blank ...
Page 188: ...Log Functions 176 Page intentionally left blank ...
Page 236: ...Troubleshooting 224 Page intentionally left blank ...
Page 252: ...Internal Battery Replacement 240 Page intentionally left blank ...
Page 258: ...Glossary of Command References 246 Page intentionally left blank ...