Events and Action Routines
194
Examples:
Alarm/Event
Action Routine
Parameters
Comments
.AUTHFAIL
PAGE
This example calls a pager at the default number, when an authorization failure occurs, and
delivers the default message to the pager.
Alarm/Event
Action Routine
Parameters
Comments
.BAT48LOW
PAGE
5551324,9990001
This example calls a pager at the number 555-1324 and delivers the message "9990001" when
the battery voltage falls below the set limit.
14.4.10 PHIRIS Action Routine
The PHIRIS Action Routine places a call to the IRISSM alarm collection package and delivers the
alarm condition.
Format: PHIRIS
Resource Required:
Modem
Parameters:
phone number
1 to 3 - For home phone number 1, 2, or 3 (from system parameters)
or
Phone Number - Phone number to dial (optional)
Examples:
Alarm/Event
Action Routine
Parameters
Comments
ERR005
PHIRIS
C\ERR05
This example places a call to IRIS at Home Phone Number 1 (default) when the external event
ERR005 occurs.
Alarm/Event
Action Routine
Parameters
Comments
.BAT48LOW
PHIRIS
2
C\BATTERY LOW
This example places a call to IRIS at Home Phone Number 2 when the .BAT48LOW event
occurs.
Summary of Contents for Lucent Technologies Access Security Gateway Guard
Page 12: ...x Page intentionally left blank ...
Page 28: ...ASG Guard Overview 16 Page intentionally left blank ...
Page 36: ...Physical Connections 24 Page intentionally left blank ...
Page 60: ...Modem Port Setup 48 Page intentionally left blank ...
Page 82: ...Modifying the User Database 70 Page intentionally left blank ...
Page 120: ...Action and Event Tables 108 Page intentionally left blank ...
Page 158: ...User Connectivity 146 Page intentionally left blank ...
Page 188: ...Log Functions 176 Page intentionally left blank ...
Page 236: ...Troubleshooting 224 Page intentionally left blank ...
Page 252: ...Internal Battery Replacement 240 Page intentionally left blank ...
Page 258: ...Glossary of Command References 246 Page intentionally left blank ...