Physical Connections
20
3.3 Installation of the ASG Guard/ASG Guard Plus
3.3.1 Cables and Equipment Required
The following cables and equipment are required for installing the ASG Guard/ASG Guard Plus:
•
A local terminal or a PC running a terminal emulation program. It will be used to initialize the
ASG Guard/ASG Guard Plus and to administer the Aux port (RS-232 9-pin connection). The
terminal should have a standard RS-232 (serial) interface for connection to DCE equipment.
Use the following terminal settings
unless the ASG Guard/ASG Guard Plus has been
preconfigured and requires the terminal to have different settings
.
•
asynchronous
•
9600
bps
•
8 bit character length, one stop bit, no parity
•
XON/XOFF (software) flow control
NOTE:
These settings can be changed after the ASG Guard/ASG Guard Plus has been
initialized.
•
9-pin male-to-female RS-232C cables (one for each resource to be protected, plus one for
the administration terminal)
•
Telephone cords with RJ11 connectors (one for each modem)
•
Network cable with an AUI or 10base-T connector
•
Null modem cables/adapters (as required) if connecting a DCE device to the Host port
3.3.2 Requirements for Network Applications
For network applications, you will also need to assign the ASG Guard/ASG Guard Plus an IP
address. Default addresses are provided, but you should obtain addresses that are appropriate
for your network from the network administrator.
3.3.3 Install the Unit
The ASG Guard/ASG Guard Plus is installed between the port(s) of a host and/or PBX and the
terminal or PC of a remote user who accesses the host(s) and/or PBX via phone line(s). Figure 3-
3 shows the cable connections for the unit.
To install the ASG Guard/ASG Guard Plus:
1.
Place the ASG Guard/ASG Guard Plus in the location you want.
If you want to rack mount the unit, perform the following steps:
a.
Place a wing on each side panel of the ASG Guard/ASG Guard Plus.
b.
Bolt the wings in place by inserting and tightening screws in the two holes on the wing
front panel and two screws in the bottom wing panel.
c.
After the wings are attached, place the ASG Guard/ASG Guard Plus in the rack.
Summary of Contents for Lucent Technologies Access Security Gateway Guard
Page 12: ...x Page intentionally left blank ...
Page 28: ...ASG Guard Overview 16 Page intentionally left blank ...
Page 36: ...Physical Connections 24 Page intentionally left blank ...
Page 60: ...Modem Port Setup 48 Page intentionally left blank ...
Page 82: ...Modifying the User Database 70 Page intentionally left blank ...
Page 120: ...Action and Event Tables 108 Page intentionally left blank ...
Page 158: ...User Connectivity 146 Page intentionally left blank ...
Page 188: ...Log Functions 176 Page intentionally left blank ...
Page 236: ...Troubleshooting 224 Page intentionally left blank ...
Page 252: ...Internal Battery Replacement 240 Page intentionally left blank ...
Page 258: ...Glossary of Command References 246 Page intentionally left blank ...