Basic Configuration
32
4.3 Specify Network Parameters
If the ASG Guard/ASG Guard Plus is part of a network, it is necessary to set both the Ethernet
and IP addresses that are appropriate for your system. To display the Set Network Parameters
screen, type SNP at the system prompt. For a detailed explanation, refer to Section 12.7.1.
>snp
--- Set Network Params ---
1 = Network Initialization Params
2 = SNMP Manager Params
3 = FTP Params
Select Group -->1
Restore Factory Defaults ? No
-- Network Initialization Parameters --
Start Network on Power-up ? No
Ethernet Address (hhhhhhhhhhhh) 08 01 02 00 03 E9
IP Address (nnn.nnn.nnn.nnn) 192.9.200.2
PPP Address (nnn.nnn.nnn.nnn) 192.9.200.3
Default Gateway (nnn.nnn.nnn.nnn)
To start the network type STARTNET
07/17/96 15:55:36 [A] Set Network Params - O.K.
Screen 4-7. Set Network Params Screen
For a detailed explanation of Group 1 Network Initialization Params, refer to Section 12.4.
For a detailed explanation of Group 2 SNMP Manager Params, refer to Section 12.5 and 12.7.
For a detailed explanation of Group 3 FTP Params, refer to Section 12.11.
To verify that the ASG Guard/ASG Guard Plus can be accessed through the network, start the
network module by typing STARTNET at the system prompt. Access the ASG Guard/ASG Guard
Plus from a terminal on the network using the IP address that you just entered.
Summary of Contents for Lucent Technologies Access Security Gateway Guard
Page 12: ...x Page intentionally left blank ...
Page 28: ...ASG Guard Overview 16 Page intentionally left blank ...
Page 36: ...Physical Connections 24 Page intentionally left blank ...
Page 60: ...Modem Port Setup 48 Page intentionally left blank ...
Page 82: ...Modifying the User Database 70 Page intentionally left blank ...
Page 120: ...Action and Event Tables 108 Page intentionally left blank ...
Page 158: ...User Connectivity 146 Page intentionally left blank ...
Page 188: ...Log Functions 176 Page intentionally left blank ...
Page 236: ...Troubleshooting 224 Page intentionally left blank ...
Page 252: ...Internal Battery Replacement 240 Page intentionally left blank ...
Page 258: ...Glossary of Command References 246 Page intentionally left blank ...