INTUITY CONVERSANT System Version 6.0
MAP/100 New System Installation
585-310-176
Issue 3.0
June 1997
Troubleshooting Procedures
Page B-2
Repairing Power-Up Troubles
B
Repairing Power-Up Troubles
Power-up troubles are experienced when you are first turning the system on.
lists the indications related to power-up troubles:
Table B-1.
Repairing Power Up Troubles
Indication
Corrective Action
The system will not
power up.
1. Verify that the power toggle switch on the front is in the
ON position.
2. Verify all external system connections (power cords and
monitor cables) are correct (for example, the blue cable
connects to the 3270 circuit card and not to the system
parallel port).
3. Verify all external system connections are secure.
During startup, the
system displays the
following message:
“Shared memory is
marked as
invalid. cvis_
menu exiting.”
1. Stop the voice system. See “Stopping the Voice System”
in Chapter 3, “Common System Procedures,” in your
platform system maintenance book.
2. Start the voice system. See “Starting the Voice System” in
Chapter 3, “Common System Procedures,” in your
platform system maintenance book.
3. Enter
cvis_mainmenu
4. If the problem persists:
a. Stop the voice system. See “Stopping the Voice
System” in Chapter 3, “Common System Procedures,”
in your platform system maintenance book.
b. Enter
cp /gendb/shmem/devtbl gendb/shmem/devtbl.old
c. Enter
rm /gendb/shmem/devtbl
d. Start the voice system. See Chapter 3, “Common
System Procedures,” in your platform system
maintenance book.
Continued on next page