INTUITY CONVERSANT System Version 6.0
MAP/100 New System Installation
585-310-176
Issue 3.0
June 1997
Verifying System Status
Page 5-10
Activating Alarm Origination
5
Activating Alarm Origination
Remote Alarming allows a technician in the Technical Support Organization
(TSO) to receive notice that your voice system is experiencing difficulty. Alarms
levels are categorized by their severity as Critical, Major and Minor. See
I
NTUITY
™ CONVERSANT® System Version 6.0 System Alarms and Log
Messages,
585-310-182, for information about remote alarming.
To activate alarm origination, do the following:
1. Clear all alarms. See Chapter 1, “Getting Started,” in
I
NTUITY
CONVERSANT System Version 6.0 System Alarms and Log Messages,
585-310-182, for details on clearing alarms.
2. Check the tape drive for a tape. The light on the tape drive is on if it
contains a tape.
!
CAUTION:
Do not activate Alarm Origination unless the tape drive contains a
back-up tape.
If the tape drive does not contain a tape for the nightly backup, locate a
tape and insert it into the tape drive.
3. Log in as root.
4. Enter
cvis_menu
The system displays the Voice System Administration menu (
).
5. Select
The system displays the Alarm Management window (
> Remote Alarming Administration
> Configuration Management