Configuring the Control Module and System Timing
Administrative connections
Stinger® MS+ Getting Started Guide
5-5
The
cmmodemShowCountries
system-level command displays a list of countries
that the modem installed in the revision 2 control module supports. The following is
a sample output of this command:
admin>
cmmodemShowCountries
The country codes supported by this modem are:
0, Japan
9, Australia
a, Austria
f, Belgium
16, Brazil
26, China
31, Denmark
3c, Finland
3d, France
42, Germany
46, Greece
53, India
57, Ireland
59, Italy
61, Korea
6c, Malaysia
73, Mexico
7b, Netherlands
82, Norway
8a, Poland
8b, Portugal
9c, Singapore
9f, South Africa
a0, Spain
a5, Sweden
a6, Switzerland
b4, United Kingdom
b5, United States
fd, unknown
fe, Taiwan
For additional information about this parameter and these commands, see the
Stinger Reference
.
Backup management with an internal modem
Revision 2 control module models B and C are equipped with an internal modem.
This modem is configured by default to automatically answer any incoming calls. For
this reason, you need only connect the telephone line to the RJ-11 jack on the face of
the control module. Figure 5-4 shows a connection for an internal modem.