C-4
Stinger® MS+ Getting Started Guide
Safety-Related Electrical, Physical, and Environmental Information
Site specifications
Site specifications
Stinger units require a particular operating environment and minimum clearance for
proper operation (see “Space requirements”).
Operating environment
Table C-5 describes the environmental requirements for selecting an installation site
for the Stinger MS+ hardware. The site requirements are based on Network
Equipment Building System (NEBS) GR-63-CORE and GR-1089-CORE.
WAN interfaces
DS3 and E3 (cell-based), OC3c/STM-1 (optical and
electrical), T1, E1, and Ethernet
Management
interfaces
Ethernet and RS-232
Physical characteristics
Basic unit includes two dc power filters, one control
module, one trunk module, and up to four pairs of LIMs
and LPMs
Overall chassis size
a
Height: 7 inches (17.78cm)
Depth: 15.35 inches (39cm)
Width: 17.7 inches (44.9cm)
Unit weight
66 pounds (30kg) maximum (fully configured)
a.
The depth measurement does not include calculations for cable spacing.
Table C-4.
Stinger MS+ physical specifications (Continued)
Specification
Description
Table C-5.
Stinger MS+ site specifications
Parameter
Requirement
Ambient operating
temperature
0°C to 55°C (32°F to 131°F)
Relative humidity
10% to 95% (noncondensing)
Operating altitude
To 13,123 feet (4000m)
Ambient storage
temperature
-40°C to +85°C (-40°F to +185°F), 95% relative
humidity
Storage altitude
-1,000 feet to +30,000 feet (-305m to 9150m)