background image

5

INFLATOR OPERATION

TO INFLATE TIRES:

1. 

Remove and unwind 12 Volt power cord (see #13 in figure 1, page 3) from the stor-
age compartment.  See #10 in figure 1. 

2. 

Make certain the inflator power switch is in the off position.  See #1 in figure 1.

3. 

Set emergency brake and start vehicle engine.  See “Warning: Vehicle Exhaust Without 
Proper Ventilation”, page 4. 

4. 

Plug inflator lighter plug into vehicle 12 Volt cigarette lighter socket.

5. 

Check manufacturer’s recommended tire pressure specifications indicated on the tire 
sidewall.

6. 

Locate the dial pressure gauge (see #3 in figure 1) and turn the pre-set dial until the 
auto shut-off indicator/stop is set to the desired shut-off pressure.  See figure 2, page 
3. The pre-set inflation feature will automatically stop inflating once a predetermined 
pressure has been reached.

7. 

Unwind the air hose from its storage channel and attach air hose nozzle to vehicle tire 
valve stem by threading the nozzle onto the stem clockwise until secure.  See #6 in 
figure 1.  Do not turn inflator on.

NOTE:

 When the nozzle is connected correctly, wait 5-7 seconds and the gauge will 

indicate the current tire pressure.  Always follow the manufacturer’s inflation pressure rec-
ommendations to avoid over-inflation.  If the tire is over-inflated, press the deflation bleeder 
valve button to release air until pressure gauge indicates the correct pressure.  See #8 in 
figure 1.
The pressure gauge on the inflator is for reference only and is therefore not binding for 
exact values.  While inflating, the gauge is a measurement of the fluctuating pressure 
between the tire and the high pressure hose.  To reduce the risk of over-inflation, use a reli-
able pressure gauge periodically during inflation before driving a vehicle inflated with the 
inflator.   
8. 

Turn on inflator power switch to the on position. See #1 in figure 1. The BellAire™ 
3000 will now inflate your tire to the pre-set pressure level and then shut off automati-
cally.  After pre-set auto shut-off has taken place, turn inflator power switch to the off 
position.  See #1 in figure 1.

9. 

To stop inflator before reaching the pre-set auto shut-off pressure, turn inflator power 
switch to the off position.  See #1 in figure 1.

10.  Remove air hose nozzle from vehicle tire valve stem by turning air hose nozzle counter-

clockwise and return air hose to its built-in storage location on inflator.

11.  Unplug inflator from vehicle 12 Volt cigarette lighter socket and store cord in its stor-

age compartment.

12.  Turn off vehicle.

TO INFLATE SPORTS BALLS AND OTHER HIGH PRESSURE SMALL INFLATABLES:

1. 

Remove and unwind 12 Volt power cord (see #13 in figure 1, page 3) from the stor-
age compartment.  See #10 in figure 1.

2. 

Unwind air hose from its storage channel (see #6 in figure 1) and select one of the 
small adapter needles provided in the storage compartment.  See figure 3, page 3.

3. 

Attach the adapter needle to the air hose nozzle by turning the adapter needle clock-
wise.

4. 

Check manufacturer’s recommended pressure specifications for inflatable. 

5. 

Locate the dial pressure gauge (see #3 in figure 1) and turn the pre-set dial until the 
auto shut-off indicator/stop is set to the desired shut-off pressure.  See figure 2, page 
3. The pre-set inflation feature will automatically stop inflating once a predetermined 
pressure has been reached. 

6. 

Insert adapter needle into inflatable.

Summary of Contents for BellAire 3000

Page 1: ...or Gonfleur de pneu BellAire3000 ATTENTION READ ALL INSTRUCTIONS AND WARNINGS CAREFULLY BEFORE USE ATTENTION LIRE ATTENTIVEMENT TOUTES LES INSTRUCTIONS ET TOUS LES AVERTISSEMENTS AVANT L EMPLOI INFLAT...

Page 2: ...e product better and safer SYMBOL NAME DESIGNATION EXPLANATION Safety Alert Read The Operator s Manual Eye Protection Wet Conditions Alert Hot Surface Indicates a potential personal injury hazard To r...

Page 3: ...Bleeder Valve 9 Inflator Needle Kit 10 Storage Compartment Door 11 Storage Door Release Latch 12 12 Volt Power Cord Exit Slot 13 10 Foot 3 m 12 Volt Power Cord with replaceable fuse 14 Air Intake Exh...

Page 4: ...wer cord or air hose Do not over stretch power cord or air hose Never point an inflator air hose toward yourself others or animals Never start a vehicle with the inflator plugged into the DC 12 Volt p...

Page 5: ...between the tire and the high pressure hose To reduce the risk of over inflation use a reli able pressure gauge periodically during inflation before driving a vehicle inflated with the inflator 8 Turn...

Page 6: ...requiring 10 PSI 0 69 bars or less inflate in short bursts and check by feel or by a reliable measuring device to determine accurate pressure 10 Turn on inflator power switch to the on position See 1...

Page 7: ...blown See fuse replacement instructions in the maintenance section See figure 4 above Inflator fails to stop at the auto shut off pre set pressure Check to make sure auto shut off pressure settings ar...

Page 8: ...than the operating instructions disassembly repair or alteration by anyone other than Bell Automotive Products Inc Further the warranty does not cover Acts of God such as fire flood hurricanes and to...

Page 9: ...9 NOTES REMARQUES...

Page 10: ...lisation Protection oculaire Alerte concernant les envi ronnements humides Surface chaude Indique un risque de blessure corporelle potentiel Pour limiter les risques de blessures l utilisateur doit li...

Page 11: ...10 Porte du compartiment de rangement 11 Loquet de d blocage de la porte du compartiment de rangement 12 Fente de sortie du cordon d alimentation 12 volts 13 Cordon d alimentation 12 volts de 10 pieds...

Page 12: ...le cordon d alimentation ou le conduit d air Ne pas tirer exag r ment sur le cordon d alimentation ou le conduit d air Ne jamais orienter le conduit d air d un gonfleur sur soi sur d autres personnes...

Page 13: ...b rant l air jusqu ce que le manom tre indique la bonne pression Voir n 8 Figure 1 Le manom tre du gonfleur est fourni titre de r f rence uniquement et ses valeurs sont juste indicatives Lors du gonfl...

Page 14: ...itre de r f rence uniquement et ses valeurs sont juste indicatives Lors du gonflage le manom tre mesure la pression fluctuante entre l objet gonfler et le conduit haute pression Pour gonfler des objet...

Page 15: ...de remplacement du fusible dans la section Entretien Voir Figure 4 ci dessus Le gonfleur ne s arr te pas la pression d arr t automatique pr r gl e V rifier que les r glages de pression d arr t automa...

Page 16: ...ou utilisation impropre du produit utilisation d une tension ou d un courant inappropri utilisation commerciale du produit utilisation non conforme au mode d emploi d montage r paration ou alt ration...